Using a steel conduit to protect the transducer cable
A steel conduit must be used to protect the transducer cable. The steel conduit must
preferably be straight. Start the conduit immediately above the transducer, and terminate it
well above the water line.
It is strongly recommended to lay a steel conduit from the cable gland above the transducer
to the ES80 transceiver, and to pull the transducer cable through this conduit. The conduit
serves two purposes. It will protect the cable, and shield it from electric noise. Depending
on how the steel conduit is terminated over the transducer, it may also secure the watertight
integrity of the vessel.
There are several reasons for this.
• It will make it easier at a later stage to replace the transducer.
• It will protect the cables.
• Noise and interference from other electrical equipment is greatly reduced.
• The risk of flooding is greatly reduced when the steel conduit is terminated above the
water line.
With a steel conduit the installation will satisfy the European Union regulations for
electromagnetic compatibility (EMC) interference. Without a steel conduit, there is a risk of
reduced ES80 performance.
Steel conduit quality and shielding
The steel conduit must be unbroken and watertight from the transducer to above the water
line. From there, the cable can be pulled further, or a junction box can be installed to
facilitate further connections.
Note
The steel conduit must act as a continuous electrical screen all the way.
If two or more transducers are installed close to each other it is possible to pull their cables
in the same steel conduit, provided the conduit diameter is increased accordingly. However,
for easy replacement it is recommended that each transducer has its own steel conduit.
Simrad ES80 Installation Manual
Summary of Contents for Simrad ES80
Page 1: ...kongsberg com simrad Simrad ES80 INSTALLATION MANUAL ...
Page 2: ......
Page 25: ...416739 A 23 Related topics Scope of supply page 21 Simrad ES80 page 11 Simrad ES80 ...
Page 278: ...276 416739 A 201575 Transducer connector assembly and wiring Simrad ES80 Installation Manual ...
Page 309: ......
Page 310: ... 2020 Kongsberg Maritime ISBN 978 82 8066 187 6 ...
Page 311: ......
Page 312: ...Installation Manual Simrad ES80 ...