416739/A
119
Ground cable
Correct grounding is essential for safe operation and maximum performance.
A
Ground tag on unit
B
Vessel ground
The ground connection is made using a thick stranded (or
yellow/green) cable making a solid connection between the
cabinet and the bulkhead. It is normally provided with a
green/yellow colour. The grounding cable must be connected to
vessel ground in the fuse box, or other common grounding point.
Minimum cable requirements
•
Conductors
: 1 x 6 mm
2
•
Screen
: None
•
Voltage
: 60 V
•
Maximum outer diameter
: Not applicable
Related topics
Cable drawings and specifications, page 116
Cable layout and interconnections, page 79