Installation
20220505H
79
Electrical connection
JUNCTION UNIT
MAIN PCB
RF
RF+
Rudder
Feedb.
LFI3000 Mk2
LINEAR FEEDBACK
INTERFACE
TB1
Wh
ite
Br
ow
n
TB2
Wh
ite
Br
ow
n
Gr
ee
n
Ye
llo
w
Figure 4-27 LF3000/LFI3000 Mk2 connections
Note !
The previous LFI3000 had no centre block terminal for screen
termination.
4.28
CD100A Course Detector
On some installations the owner may prefer to use the boats own
compass. The compass must be fully gimballed and have a flat
surface underneath to fit the CD100A. Make hole for a 6 mm
screw in the bottom of the compass and mount the CD100A as
shown on the drawing. Secure the 6 mm screw through the
centre hole of the CD100A. Make sure the cable does not
prevent the compass from moving freely in the gimbals.
3
2
1
4
5
6
Figure 4-28 CD100A mounting
1 Screw M6x25mm, non
magnetic
2 Washer, non magnetic
3 Course
detector
4 Cable clamp, nylon
5 Washer, non magnetic
6 Screw M3x10mm, non
magnetic
Note!
Lock nut on mounting screw
(pos. 1) for transportation only.