413764/B
83
Note
Beware of Electrostatic Discharge (ESD)!
When you handle electronic circuit boards and modules, you must beware of the dangers
of electrostatic discharge (ESD), both to yourself and to the equipment. In order to
ensure safe transport and storage, circuit boards and other electronic units will always
be wrapped in a clear plastic protective bag, and the bag will be sealed.
Procedure
1
Lift the unit, in its protective bag, out of the transport box.
Note
You must never use the cables to lift or carry a unit.
2
Place it in a stable position on the floor or on the workbench.
3
Inspect the unit for damage.
a
If a unit has been damaged, prepare an inspection report stating the condition
of the unit and actions taken.
b
Describe the damage, and collect photographic evidence if possible. Return
the inspection report to Kongsberg Maritime as soon as possible.
4
Assuming all is well, open the bag and remove the unit.
5
Take out and keep the documentation.
You will need the documentation if the item shall be returned to us.
6
If applicable, open the unit and check inside.
7
Remove any packing and desiccant material that may be found inside the shipping
container or bag.
8
Collect and keep the relevant user manuals and/or installation documents provided
with the unit.
Unpacking transducers
Prior to installation or use, transducers, sonar heads and hydrophones must be unpacked
from their transport boxes. It is important that this unpacking is done without inflicting
damage to the equipment.
Prerequisites
Observe the procedure for unpacking of standard parts and units.
Summary of Contents for EA640
Page 62: ...62 413764 B 388697 WBT outline dimensions EA640 Installation Manual ...
Page 63: ...413764 B 63 Drawing file ...
Page 64: ...64 413764 B 400930 WBT Cabinet outline dimensions EA640 Installation Manual ...
Page 65: ...413764 B 65 Drawing file ...
Page 66: ...66 413764 B EA640 Installation Manual ...
Page 67: ...413764 B 67 Drawing file ...
Page 93: ......
Page 94: ... 2018 Kongsberg Maritime ...