APPENDIX H. DRIVE FAULTS
H.1
Drive Fault F0105
Step
Check
Possible cause
Action
1
F0105 is continuously active
(power on, elevator on stand-by
mode)?
Mains wires on drive
connectors X4-X6 (marked as
T1, T2, T3) are loosely
connected.
Tighten the mains
wires carefully to X4-
X6 connectors (T1,
T2, T3).
Hint:
Turn power OFF from the main power switch. Then
open carefully the screws in the terminal block (T1, T2,
T3) and check that it is in good condition. Push wires
tightly against the bottom of the terminal block, while
fastening the screws.
a
F0105 is still active?
Defective V3F16L.
Replace the defective
V3F16L.
2
F0105 and F0103 are
continuously active (power on,
elevator on stand-by mode)?
Mains wires on drive
connectors X4-X6 (marked as
T1, T2, T3) are loosely
connected.
Tighten the mains
wires carefully to X4-
X6 connectors (T1,
T2, T3).
Hint:
Turn power OFF from the main power switch. Then
open carefully the screws in the terminal block (T1, T2,
T3) and check that it is in good condition. Push wires
tightly against the bottom of the terminal block, while
fastening the screws.
a
Faults still active?
Loose charge resistor cable
inside the V3F16L.
Replace the defective
drive.
3
F0105 during drive (light
direction) and
F0026, F0036 and F0103?
Loose brake resistor connector
XBRE2.
Tighten the loose
connector / wires.
4
F0105 during drive (light
direction) but without
F0026, F0036 and F0103?
Old module revision
(R.1.4 or R.1.5).
Update the old
module to R.1.5.1 or
newer.
a
F0105 is still active?
Defective V3F16L module
(for example loose C12).
Replace the defective
V3F16L.