AS-10.22.027
44 (54)
(-) 2006-11-10
KONE MonoSpace®
Maintenance Instruction
© 2006 KONE Corporation
All rights reserved.
Disclosure prohibited
5
The led/leds in LCECCB stays
ON when XB27 is unplugged?
Defective LCECCB.
Replace the defective
LCECCB.
6
The problem appears only
seldom or on a certain floor?
Incorrectly adjusted magnet,
Check the floors
where the problem
appears. Adjust the
magnets or switches,
if necessary. Remove
extra bolts.
extra pulses caused by some
extra bolts,
incorrectly adjusted bistable
switch or
problem caused by adjacent
magnet.
Step
Check
Possible cause