AS-10.22.027
38 (54)
(-) 2006-11-10
KONE MonoSpace®
Maintenance Instruction
© 2006 KONE Corporation
All rights reserved.
Disclosure prohibited
E.2
SPEED > 0,1m/s Led is not working or fault codes F0082, F0015 appear
Step
Check
Possible cause
Action
1
Speed >0,1 m/s Led is working
correctly but faults F0082 and
F0015 appear?
Probably a defective LCEADO.
Replace the defective
LCEADO.
2
Elevator is running but Speed >
0,1 m/s Led is OFF all the time?
Most probably a defective
LCECPUnc or V3F16L.
Replace the defective
LCECPUnc / V3F16L.
3
Speed > 0,1m/s Led is ON all
the time, F0082 and F0015
appear when the elevator goes
to the terminal floor?
Signal is cut between
LCECPUnc and V3F16L,
defective or loose flat cable.
Ensure that the cable
is not loose. Replace
the cable if it is
defective.
a
The problem is not solved.
Defective LCECPUnc or
defective V3F16L.
Replace the defective
LCECPUnc or
V3F16L.