APPENDIX E. DRIVE RELATED LEDS NOT OK
E.1
V3F OK Led is OFF (F0026)
Hint:
V3F OK Led OFF means that communication between LCE and drive is not working or the drive
sees a fault and sends inverter not OK status to LCE, which puts V3FOK Led off.
Step
Check
Possible cause
Action
1
Check menu 1 95.
Incorrect drive type LCE
parameter.
Use the menu to
correct the parameter.
2
F0026 is the only fault in the
fault log?
Defective flat cable between
V3F16L and LCECPUnc,
defective V3F16L, broken
V3F16L D13 or D9 EPROM
socket or wrong placing of
EPROMS.
Change the flat cable
if it is defective. Check
the EPROM sockets
inside the drive.
Replace the defective
component.
3
COM fault Led in V3F16L is not
blinking?
Serial communication between
drive and LCE is not working.
Hint:
Refer to drive fault code
list 804611 V3F16L/V3F16R
Drive Fault Codes.
Replace the defective
LCECPUnc or
V3F16L.