2
F2 fuse seems to be OK but
blows when the elevator tries
to run?
Proceed to Step 2a.
a
Check the brakes and the
wiring:
Unplug XBR3 and measure
the resistance of the brake
coils between pin 1 and 3,
and between 2 and 3.
Typical values for brake coil
resistance are
- for MX5 and MX6:
320 Ohm (+/-20 Ohm),
- for MX10:
220 Ohm (+/-20 Ohm).
Is the measured resistance
below the typical value?
Short circuit in the brake
coil.
Replace the defective brake
module.
b
F2 fuse blows when the
elevator tries to run and the
brake coil resistance
indicates that the brake coil is
OK.
Brake power circuit failure
on V3F16L.
Replace the defective
V3F16L.
Step
Check / Symptom
Possible cause
Action