Replace hydraulic filter element
On a new machine, replace the element after the first 100 to
150 hours, then perform further replacement of the element ac-
cording to the table on the right.
Change of oil in hydraulic tank
Change the oil according to the table.
Replace additional filter element for breaker (if equip-
ped)
Use a guideline of 250 hours for use of the breaker (operating
ratio of the breaker: 50% or more), and replace the element ac-
cording to the table.
For detail, see “METHOD FOR REPLACING ADDITIONAL FIL-
TER ELEMENT FOR BREAKER (6-54)”.
Replace pilot filter element (if equipped)
Use a guideline of 250 hours for use of the breaker (operating
ratio of the breaker: 50% or more), and replace the element ac-
cording to the table.
For detail, see “METHOD FOR REPLACING ADDITIONAL PI-
LOT FILTER ELEMENT FOR BREAKER (6-55)”.
X: Breaker operating ratio (%)
Y: Replacement interval (H)
(A):
Hydraulic tank element, pilot filter element
(B):Hydraulic oil
(C):Element of additional filter
REMARK
Breaker operating ratio 100 % means that only the breaker is used
Breaker operating ratio 0 % means that the breaker is not used
Lubrication
When the hydraulic breaker is equipped, lubricate the machine on 100-hour intervals. For detail, see “METHOD
FOR LUBRICATING (4-46)”.
MAINTENANCE SCHEDULE
MAINTENANCE
4-14
Summary of Contents for PC360LC-11
Page 2: ......
Page 22: ......
Page 76: ......
Page 344: ......
Page 425: ...SPECIFICATIONS 5 1 ...
Page 429: ...PC360NLC 11 SPECIFICATIONS SPECIFICATIONS 5 5 ...
Page 430: ......
Page 450: ...PC360LC 11 2 Piece Boom PC360NLC 11 2 Piece Boom 2 PIECE BOOM ATTACHMENTS AND OPTIONS 6 20 ...
Page 457: ...ATTACHMENTS AND OPTIONS 17M LONG REACH BOOM AND ARM 6 27 ...
Page 465: ...ATTACHMENTS AND OPTIONS SUPER LONG FRONT BOOM AND ARM 6 35 ...
Page 499: ...REPLACEMENT PARTS 7 1 ...
Page 515: ......