Battery disconnect switch (1) is used for cutting out the electric-
ity from the battery.
This switch is installed inside the cover on the left side of the
machine.
Raise rubber cover (2), and the switch is seen.
REMARK
Operate this switch while system operating lamp (3) is OFF.
(O): OFF position
Switch key (1) can be pulled out (and inserted) and the current
from the battery is cut out.
(I): ON position
The current from the battery flows into the circuit.
Before starting the machine, be sure to set the switch to this
position.
SYSTEM OPERATING LAMP
System operating lamp (1) indicates that the controller mount-
ed on the machine is turned ON.
Lamp (1) lights up in green when the controller is turned ON
and goes out in 2 to 6 minutes after the starting switch is turned
to OFF position.
Before operating the battery disconnect switch, check that lamp
(1) is not lit.
NOTICE
If the battery disconnect switch is turned OFF while this
lamp is lit, the data in the controller may be lost.
REMARK
• Even if the starting switch is in OFF position, the controller may operate. The lamp lights up in this case, but
it is not abnormal.
• After the starting switch has been turned OFF, the system operating lamp may stay lit for a long time.
In such case, consult your Komatsu distributor.
EXPLANATION OF COMPONENTS
OPERATION
3-112
Summary of Contents for PC360LC-11
Page 2: ......
Page 22: ......
Page 76: ......
Page 344: ......
Page 425: ...SPECIFICATIONS 5 1 ...
Page 429: ...PC360NLC 11 SPECIFICATIONS SPECIFICATIONS 5 5 ...
Page 430: ......
Page 450: ...PC360LC 11 2 Piece Boom PC360NLC 11 2 Piece Boom 2 PIECE BOOM ATTACHMENTS AND OPTIONS 6 20 ...
Page 457: ...ATTACHMENTS AND OPTIONS 17M LONG REACH BOOM AND ARM 6 27 ...
Page 465: ...ATTACHMENTS AND OPTIONS SUPER LONG FRONT BOOM AND ARM 6 35 ...
Page 499: ...REPLACEMENT PARTS 7 1 ...
Page 515: ......