117
LONG PERIODS OF INACTIVITY
3.13.2 DURING THE PERIOD OF INACTIVITY
3.13.3 AFTER THE PERIOD OF INACTIVITY
DANGER
•
If it is necessary to carry out a rust-prevention treatment while the machine is kept indoors, open doors
and windows to increase ventilation and avoid poisoning by gas.
Start the engine and move the machine for a short distance once a month, so that a new oil film covers all the mov-
ing parts and the surfaces of the components. Provide also for charging the battery
IMPORTANT
☞
•
If the machine is stored without carrying out the monthly rust-prevention treatment, have maintenance
performed by your Komatsu Utility Dealer.
When using the machine after a long period of inactivity, proceed as follows:
1 - Free the exhaust pipe and the fuel tank from the seals.
2 - Check all the levels (engine oil, coolant, fuel, hydraulic circuit oil).
3 - Make sure that the battery is charged and install it on the machine.
4 - Disconnect the engine stop solenoid.
5 - Turn the ignition key directly to the start position and keep it there until the engine oil pressure warning light
goes out.
This operation serves to restore the lubricating oil circulation and to carry out a first lubrication cycle.
6 - Reconnect the engine stop solenoid and start the engine.
7 - Start the engine and let it idle for approximately 20 minutes.
8 - While warming up the engine, remove the protection grease from the hydraulic cylinder rods.
9 - Before moving the machine, make sure that the instruments, the warning lights and the working lights operate
correctly.
10 - Warm up the hydraulic cylinders as soon as possible, by slowly moving all the equipment.
Summary of Contents for PC110R-1
Page 2: ......
Page 19: ...17 SAFETY AND ACCIDENT PREVENTION...
Page 51: ...49 THE MACHINE AND ITS OPERATIONS...
Page 126: ...124 PAGE INTENTIONALLY LEFT BLANK...
Page 127: ...125 MAINTENANCE...
Page 190: ...188 PAGE INTENTIONALLY LEFT BLANK...
Page 191: ...189 TECHNICAL SPECIFICATIONS...
Page 198: ...196 PAGE INTENTIONALLY LEFT BLANK...
Page 199: ...197 AUTHORISED OPTIONAL EQUIPMENT...