E(AR)-6
Cargo-handling System Monitoring Item
Monitoring Item
Content of Function
Range
Normal Value
Remark
Lift1 Switch
〔
Valid when the option is installed
〕
When the 1st stage switch at the lift lever lift-up side
is operating, [1] is displayed.
0:OFF
1:ON
-
Lift slow speed elevating command
switch
Lift2 Switch
〔
Valid when the option is installed
〕
When the 2nd stage switch at the lift lever lift-up side
is operating, [1] is displayed.
0:OFF
1:ON
-
Lift fast speed elevating command
switch
Lift3 Switch
〔
Valid when the option is installed
〕
When the detection switch at the lift lever lift-down
side is operating, [1] is displayed.
0:OFF
1:ON
-
Tilt Switch
When the tilt is operating, [1] is displayed.
0:OFF
1:ON
-
Reach Switch
When reach-in and reach-out are operating, [1] is
displayed.
0:OFF
1:ON
-
ATT1 Switch
When the ATT 1 is operating, [1] is displayed.
0:OFF
1:ON
-
ATT2 Switch
When the ATT 2 is operating, [1] is displayed.
0:OFF
1:ON
-
Neutral safety
When turning on the key switch with the
cargo-handling lever in the ON state, [1] is
displayed.
0
:
Normal
1
:
Abnormal
-
Lift interrupt flag state flag
When the battery remaining is below 20% and the
cargo-handling is limited, [1] is displayed.
0:21% and more
1
:20% and less
-
Lift lock valve operation
When the lock valve to inhibit the lift falling operation
is allowed to fall the lift, [1] is displayed.
0:Lock
1:Unlock
-
Automatic lift height controller selection
When the automatic lift height controller (option) is
connected, [1] is displayed.
0: Not selected
1:
Selected
-
When [0] is displayed, the automatic
lifting-high controller does not function.
Lift potentiometer open degree
It displays the operating amount of lift lever by ratio.
0
~
100
(%)
0
~
100
(%)
Revolution of cargo-handling motor
It displays the revolution of cargo-handling motor.
0
~
3500
(rpm)
0
~
3500
(rpm)
Cargo-handling motor temperature
It displays the temperature inside the cargo-handling
motor.
0
~
200
(degC)
0
~
160
(degC)
Warning
:
163 degree C
Abnormal
:
175 degree C
Cargo-handling power module temperature
It displays the temperature inside the cargo-handling
controller.
0
~
200
(degree C)
0
~
105
(degC)
Warning
:
108 degree C
Abnormal
:
120 degree C
Lift pressure sensor value
It displays the value inputted to the lift pressure
sensor by kg/cm
2
.
0.00
~
204.00
(kg/cm
2
)
0.00
~
204.00
(kg/cm
2
)
Lift height controller output
It
displays
the
voltage
inputted
to
the
cargo-controller.
0
~
5
(V)
0
~
5
(V)
When
the
voltage
is
high,
the
cargo-handling motor revolution increases.
Summary of Contents for AE50
Page 2: ...J 1 LYM2008K0099J...
Page 16: ...J AR 1...
Page 23: ...J AR 8 0 0 1 RL 1 RS RW 1 0 0 1 RL 1 RS RW 0 ON OFF 0 OFF 1 ON SW ON 0 OFF 1 ON...
Page 26: ...E 1 LYM2008K0099E Parameter Sheet for AE50 AM50...
Page 40: ...E AR 1 Parameter Sheet for AR50...
Page 50: ...CN 1 LYM2008K0099CN for AE50 AM50 for AE50 AM50 for AE50 AM50 for AE50 AM50...
Page 60: ...CN 11 ON 1 0 OFF 1 ON MODE 1 0 OFF 1 ON 1 0 OFF 1 ON 1 0 OFF 1 ON 1 0 OFF 1 ON...
Page 62: ...CN AR 1 for for for for AR50 AR50 AR50 AR50...
Page 69: ...CN AR 8 1 0 1 0 1 RL 1 RS RW 1 2 0 1 0 1 RL 1 RS RW 0 ON OFF 1 0 OFF 1 ON 1 0 OFF 1 ON...
Page 72: ...RU 1 LYM2008K0099RU AE50 AM50...
Page 76: ...RU 5 0 1 1 0 0 1 3 1 240 30 5 240 OFF 5 5 240 F R 0 0 F R 1 0 1 0 0 1 0 1...
Page 77: ...RU 6 0 00 50 00 c 2 5 00 20 00 2 0 2 0 K 2 AE50 AM50 1 0 50 3 00 0 10 0 40...
Page 86: ...RU AR 1 AR50...