E-10
Meter Monitor Item
Monitoring Item
Content of Function
Range
Normal Value
Remark
BDI
To display battery state-of-charge
0 - 100(%)
0 - 100%
Battery Voltage
To display battery voltage.
30.0 - 60.0 (V)
47.0 - 55.0 (V)
Key ON Time
To display cumulative time of key ON state
0 - 99999.9 (h)
0 - 99999.9 (h)
R Motor Operating Hours
To display cumulative time of F/R lever ON state of R
motor.
0 - 99999.9 (h)
0 - 99999.9 (h)
R Motor Actual Operating Hours
To display cumulative time of R motor command.
0 - 99999.9 (h)
0 - 99999.9 (h)
R Motor Hour-Meter Reading
To display operating hours of R motor on meter panel
0 - 99999.9 (h)
0 - 99999.9 (h)
L Motor Operating Hours
To display cumulative time of F/R lever ON state of L
motor.
0 - 99999.9 (h)
0 - 99999.9 (h)
L Motor Actual Operating Hours
To display cumulative time of L motor command.
0 - 99999.9 (h)
0 - 99999.9 (h)
L Motor Hour-Meter Reading
To display operating hours of L motor on meter
panel.
0 - 99999.9 (h)
0 - 99999.9 (h)
Pump Motor Operating Hours
To display cumulative time of lift lever ON state of
pump motor.
0 - 99999.9 (h)
0 - 99999.9 (h)
Pump Motor Actual Operating Hours
To display cumulative time of pump motor command.
0 - 99999.9 (h)
0 - 99999.9 (h)
Pump Motor Hour-Meter Reading
To display operating hours of pump motor command.
0 - 99999.9 (h)
0 - 99999.9 (h)
R motor hour-meter startup swch state
To display [1] when connecting hour-meter startup
wiring of pump motor.
0/1
-
1: The hour-meter startup switch wiring
is connected.
L motor hour-meter startup swch state
To display [1] when connecting hour-meter startup
wiring of pump motor.
0/1
-
1: The hour-meter startup switch wiring
is connected.
Pump motor hour-meter startup swch state
To display [1] when connecting hour-meter startup
wiring of pump motor.
0/1
-
1: The hour-meter startup switch wiring
is connected.
Electrolyte Level Switch
To display [1] when electrolyte level is normal.
0: Low
1: Normal
-
Electrolyte Level Sensor Availability Signal
To display [1] when electrolyte level sensor is
equipped with vehicle.
0: Not available
1: Available
-
Controller Cooling Fan ON/OFF
To display [1] when cooling fan is working.
0:OFF
1:ON
-
Summary of Contents for AE50
Page 2: ...J 1 LYM2008K0099J...
Page 16: ...J AR 1...
Page 23: ...J AR 8 0 0 1 RL 1 RS RW 1 0 0 1 RL 1 RS RW 0 ON OFF 0 OFF 1 ON SW ON 0 OFF 1 ON...
Page 26: ...E 1 LYM2008K0099E Parameter Sheet for AE50 AM50...
Page 40: ...E AR 1 Parameter Sheet for AR50...
Page 50: ...CN 1 LYM2008K0099CN for AE50 AM50 for AE50 AM50 for AE50 AM50 for AE50 AM50...
Page 60: ...CN 11 ON 1 0 OFF 1 ON MODE 1 0 OFF 1 ON 1 0 OFF 1 ON 1 0 OFF 1 ON 1 0 OFF 1 ON...
Page 62: ...CN AR 1 for for for for AR50 AR50 AR50 AR50...
Page 69: ...CN AR 8 1 0 1 0 1 RL 1 RS RW 1 2 0 1 0 1 RL 1 RS RW 0 ON OFF 1 0 OFF 1 ON 1 0 OFF 1 ON...
Page 72: ...RU 1 LYM2008K0099RU AE50 AM50...
Page 76: ...RU 5 0 1 1 0 0 1 3 1 240 30 5 240 OFF 5 5 240 F R 0 0 F R 1 0 1 0 0 1 0 1...
Page 77: ...RU 6 0 00 50 00 c 2 5 00 20 00 2 0 2 0 K 2 AE50 AM50 1 0 50 3 00 0 10 0 40...
Page 86: ...RU AR 1 AR50...
Page 94: ...RU AR 9 1 0 1 0 1 RL 1 RS RW 1 2 0 1 0 1 RL 1 RS RW 0 1 0 1 1 0 1...