E-13
Power Supply Controller2 (Hybrid vehicle only)
Monitoring Item
Content of Function
Range
Normal Value
Remark
Battery Temperature CH0 U (Up)
-61.45 - 146.04
(degC)
49.9 or less
(degC)
Caution : 50degC
Warning : 55degC
Battery Temperature CH0 D (Down)
The temperature of battery (the lower) is displayed.
-61.45 - 146.04
(degC)
49.9 or less
(degC)
Caution : 50degC
Warning : 55degC
Battery Temperature CH1 U (Up)
-61.45 - 146.04
(degC)
49.9 or less
(degC)
Caution : 50degC
Warning : 55degC
Battery Temperature CH1 D (Down)
The temperature of battery (the middle) is displayed.
-61.45 - 146.04
(degC)
49.9 or less
(degC)
Caution : 50degC
Warning : 55degC
Battery Temperature CH2 U (Up)
-61.45 - 146.04
(degC)
49.9 or less
(degC)
Caution : 50degC
Warning : 55degC
Battery Temperature CH2 D (Down)
The temperature of battery (the upper) is displayed.
-61.45 - 146.04
(degC)
49.9 or less
(degC)
Caution : 50degC
Warning : 55degC
Power PC Board 0 Heat Sink
Temperature
The temperature of power PC board 0 inside controller is
displayed.
-36.11 - 224.35
(degC)
94.9 or less
(degC)
Caution : 95degC
Warning : 100degC
Power PC Board 1 Heat Sink
Temperature
The temperature of power PC board 1 inside controller is
displayed.
-36.11 - 224.35
(degC)
94.9 or less
(degC)
Caution : 95degC
Warning : 100degC
Power PC Board 2 Heat Sink
Temperature
The temperature of power PC board 2 inside controller is
displayed.
-36.11 - 224.35
(degC)
94.9 or less
(degC)
Caution : 95degC
Warning : 100degC
IGBT Temperature
The temperature of IGBT element is displayed.
-36.11 - 224.35
(degC)
109.9 or less
(degC)
Caution : 110degC
Warning : 115degC
AC200V Condenser Temperature
The temperature of condenser is displayed.
-36.11- 224.35
(degC)
69.9 or less
(degC)
Caution : 70degC
Warning : 75degC
AC200V Diode (Transformer)
Temperature
The temperature of diode (transformer) is displayed.
-36.11- 224.35
(degC)
119.9 or less
(degC)
Caution : 120degC
Warning : 125degC
Capacitor Temperature
The temperature of capacitor is displayed.
-61.45 - 146.04
(degC)
54.9 or less
(degC)
Caution : 55degC
Warning : 60degC
BDI (Power Source Controller)
The BDI data value detected by power supply controller is
displayed.
0 - 100
(%)
0 - 100
(%)
Output Limit Demand
[1] is displayed when power supply controller is outputting as to
instructions to limit output at the time of the occurrence of an
error.
0/1
-
0: Output limitation instruction
release
1: instructing
Motion Stop Demand
[
1
] is displayed when the power supply controller is outputting
as to instructions to stop operation at the time of the occurrence
of an error.
0/1
-
0: Operation stop instruction
release
1 instructing
* The display of I/O monitor is available only when key is ON or under discharge mode. The monitoring by the tool is not available when battery is under charge or under precharge.
Summary of Contents for AE50
Page 2: ...J 1 LYM2008K0099J...
Page 16: ...J AR 1...
Page 23: ...J AR 8 0 0 1 RL 1 RS RW 1 0 0 1 RL 1 RS RW 0 ON OFF 0 OFF 1 ON SW ON 0 OFF 1 ON...
Page 26: ...E 1 LYM2008K0099E Parameter Sheet for AE50 AM50...
Page 40: ...E AR 1 Parameter Sheet for AR50...
Page 50: ...CN 1 LYM2008K0099CN for AE50 AM50 for AE50 AM50 for AE50 AM50 for AE50 AM50...
Page 60: ...CN 11 ON 1 0 OFF 1 ON MODE 1 0 OFF 1 ON 1 0 OFF 1 ON 1 0 OFF 1 ON 1 0 OFF 1 ON...
Page 62: ...CN AR 1 for for for for AR50 AR50 AR50 AR50...
Page 69: ...CN AR 8 1 0 1 0 1 RL 1 RS RW 1 2 0 1 0 1 RL 1 RS RW 0 ON OFF 1 0 OFF 1 ON 1 0 OFF 1 ON...
Page 72: ...RU 1 LYM2008K0099RU AE50 AM50...
Page 76: ...RU 5 0 1 1 0 0 1 3 1 240 30 5 240 OFF 5 5 240 F R 0 0 F R 1 0 1 0 0 1 0 1...
Page 77: ...RU 6 0 00 50 00 c 2 5 00 20 00 2 0 2 0 K 2 AE50 AM50 1 0 50 3 00 0 10 0 40...
Page 86: ...RU AR 1 AR50...
Page 94: ...RU AR 9 1 0 1 0 1 RL 1 RS RW 1 2 0 1 0 1 RL 1 RS RW 0 1 0 1 1 0 1...