Vers. 100822 Page 6
ATTENTION: the torque target value added to the compensation must in any case be contained in the torque
range relating to the set speed. Any invalid value will be signaled with "
Torque/ speed error
".
7) Tm Fast Spd (Time Fast Speed):
It indicates how long the screwdriver should turn at the FAST SPEED
(see point 7) before switching to the Final Speed.
This Fast Speed Time can be set from 0.3 to 10.0 sec.
To disable the function press
until you get to OFF. In this case the screwdriver will automatically start at
pre-set speed (see point 8).
CAUTION: The aim of the FAST SPEED is only to speed up the approach time in case of long screws.
Reaching the torque at higher speed will result in inaccurate torque output. To avoid inaccurate torque values
we suggest first to set a shorter time, and then increase it.
Torque reached during the FAST SPEED won’t activate the torque signal and the message “
Error FAST
SPEED
” will be displayed on the main screen and 2 beep sounds. The red led will turn on, too.
- - - - - M E N U - - P R : 1 - - - - -
6 ) C o m p e n s : 0 . 0 0 N m
7 ) T m F a s t s p d : o f f
8 ) F a s t s p d : o f f
8) Fast spd (Fast Speed):
You can select the speed of the screwdriver during the FAST SPEED. It can be
set between max speed and the Final Speed (see point 8).
This function is available only if the Fast Speed Time is ON.
9) Final Spd (Final Speed)
:
You can select any speed value of the screwdriver between nominal
(maximum speed given in the catalogue) and the minimum speed of every single screwdriver (see table with
technical data).
In # mode, the speed is also linked to the relative table of the screwdriver in use. It is therefore not possible to
select a speed not included in its torque range. In this case, the error "
Torque/speed error
" will appear and it
will not be possible to exit the speed setting until a correct speed has been selected. To switch from one speed
to another, it will be necessary to set a torque value in common for each of the two ranges.
- - - - - M E N U - - P R : 1 - - - - -
9 ) F i n a l s p d : 6 0 0 r p m
1 0 ) R u n t i m e : 2 0 . 0 s F
1 1 ) M i n t i m e : o f f
10) Runtime
:
You can set the time of a tightening, from OFF to 20.0 sec. When the pre-set time has been
reached, it results in a torque signal.
The couple reached during this time results in a signal of
Correct screw
. If the correct screw signal is not
required, set the Minimum time up to a value of 'Minimum Time -0.1sec'.
ATTENTION: Max Time must be set at 20.0 sec.
11) Min time - Minimum Time
:
You can select the minimum time of screwing from 0.1 sec to 'Max time
- 0.1s'. To disable the function press
until you get to OFF (Min time = 0).
Torque reached below the minimum time won’t activate the torque signal and will result in an error signal.
“
Below minimum time
” will be displayed on the status bar and the red led will light up. You will hear two
beep sounds, too.