Graphic Operator Terminal /
INSTALLATION
10
Modes
The mode switches have the following functions: 1=ON, 0=OFF.
Each letter in “MODE” has a corresponding mode switch
WARNING!
The modes below are to be used with caution.
MODE
Description
0000
“Run-mode” - Boot CE, normal operation.
0010
System Restore, resets the file system and registry, reinstalls the
system pro-gram (OPsys_bxxx.CAB). Restores the operator panel
to factory settings.
WARNING!
Information can accidently be lost.
0100
Image Load mode (Sysload) allows upgrading of the firmware in the
operator panel.
Note:
All files including the file system in the operator panel are
deleted when upgrading with Image Loader.
1000
Service Menu mode, the service menu for the system program is
shown.
Allows the user to set IP configuration, erase the project, calibrate
the touch screen, set the panel in Run/Transfer mode etc.
1100
Not used (Run-mode).
1110 Self-Test
xxx1
Hard reset (forces the system to reset).
2.2.2 Connections to the Controller
For information about the cables to be used when connecting the graphic operator terminal to the
controller, please refer to the help file for the driver in question.
2.2.3 Other Connections and Peripherals
Cables, peripheral equipment and accessories must be suitable for the application and its
environment. For further details or recommendations, contact Kollmorgen.