10
Figure 10. AC Input power wiring diagram
Please note the following when connecting AC input power:
• Single-phase operation is available on AKD PDMM-x00306, AKD PDMM-x00606,
and AKD PDMM-x01206 models. For a single phase AC line, connect L1 and L2,
with L3 left open circuited. The PE is connected in the same manner as 3-phase
operation.
•
A pre-installed jumper is included if the unit has internal braking resistor.
For external braking resistor use, please consult the installation manual.
Step 7: Connect AKD PDMM Communication (X32)
1. Assign an IP Address
To establish communication between the PC and the AKD PDMM, you must first set the
AKD PDMM IP address using either static or dynamic IP addressing.
a. Static IP addressing (switch setting 1 to 9):
The S1 rotary switch on the front panel of the AKD PDMM corresponds to its IP
address setting.
Figure 11. Rotary switch for static IP addressing
IP address = 192.168.0.S1
For example, if S1 is set to 3, then the IP address is 192.168.0.103
AKD PDMM
AKD PDMM Quick Start | Connect AC Input Power