Innovative Network RTK Receiver
7.2. Field operation procedure
1.
Set up a tripod on the control point, leveling and centering strictly on the measuring point.
2.
Measure the instrument height three times, the difference of the results shall not be more than 3 mm, and
average the results. The instrument height should be measured from the center of the control point to the
mark line on the instrument.(Refer to 7.1.)
3.
Record instrument number, point name, instrument height, and start time.
4.
Power on receiver, confirm the static mode, the mainframe begins to search satellites and satellite lights
begin to flash. Recording condition reached, the status light flashes in accordance with the set sampling
interval, flashing once indicates the acquisition of an epoch.
7.3. Mode Configuration
Static mode of S680N receiver is able to be set on internal web UI or on controller software (eg.GIStar for
Android). In this section, we will respectively introduce how to configure static mode on web UI and controller
software (GIStar).
Configure on Web UI
Switch on S680N receiver in normal way, then connect receiver to computer via LEMO Ethernet port, or connect
receiver to tablet or smartphone via WIFI connection. Input admin for both username and password to login the
web UI server.
Go to Configuration—General Config, switch the working mode into Static, click on
button to
confirm the settings.