28
6.DISTANCE MEASUREMENT
Before distance measurement, it usually need to confirm the setting of atmospheric
correction and prism constant. It is necessary to check I angle of the instrument at first. Please
refer to the setting steps of V0 ADJUSTMENT (i angle)
CTS-632R10M series have three kinds of measuring mode in distance measurement:
1)Prism, need to aim at the target prism. 2).Sheet, need to aim at the target sheet.
3).Non-Prism, only need to aim at the target subject.
6.1 Setting the Atmospheric Correction
The atmospheric correction can be settled to the correction value by measuring the
temperature and pressure. Refer to section 4.2 “Setting of the Atmospheric Correction”.
6.2 Setting the Prism Constant
The default value of prism constant is -30mm. If you need to choose the other prism for
measurement, please setting the correct prism constant before working. Refer to Chapter 4.3
“Setting of the Prism Constant”. The updated value is kept in the instrument even after power
off.
6.3 Distance Measurement (Continuous Measurement)
In angle measurement mode:
Operation procedure
Operation
Display
①
Aim at the center of prism
Aim