background image

20

1175284-W2-C

© Kohler Mira Limited, July 2013

Mira is a registered trade mark of 

Kohler Mira Limited.

The company reserves the right to alter 

product specifi cations without notice.

FM 14648

Guarantee

Your  product  has  the  benefit  of  our  manufacturer’s 

guarantee which starts from the date of purchase.

To activate this guarantee, please return your completed 

registration card, visit our website or free phone 0800 

0731248 within 30 days of purchase (UK only).

Within the guarantee period we will resolve defects in 

materials or workmanship, free of charge, by repairing or 

replacing parts or product as we may choose.

This guarantee is in addition to your statutory rights 

and is subject to the following conditions:

  ●  The guarantee applies solely to the original installation  

    under normal use and to the original purchaser only.

    The  product  must  be  installed  and  maintained  in 

    accordance with the instructions given in this user 

    guide.

  ●  Servicing  must  only  be  undertaken  by  us  or  our   

    appointed  representative. 

Note!

  if  a  service  visit   

    is  required  the  product  must  be  fully  installed  and  

    connected to services.

  ●  Repair under this guarantee does not extend the original

    expiry  date. The  guarantee  on  any  replacement   

    parts or product ends at the original expiry date.

  ●  For shower fi ttings or consumable items we reserve

    the right to supply replacement parts only.

The guarantee does not cover:

  ●  Call  out  charges  for  non  product  faults  (such  as 

damage or performance issues arising from incorrect 

installation,  improper use, inappropriate cleaning, 

lack  of  maintenance,  build  up  of  limescale,  frost 

damage, corrosion, system debris or blocked fi lters) 

or where no fault has been found with the product.

  ●  Water or electrical supply, waste and isolation issues.

  ●  Compensation  for  loss  of  use  of  the  product  or 

consequential loss of any kind.

  ●  Damage or defects caused if the product is repaired 

or modifi ed by persons not authorised by us or our 

appointed representative.

  ●  Routine  maintenance  or  replacement  parts  to 

comply with the requirements of the TMV 2 or TMV 

3 healthcare schemes.

  ●  Accidental or wilful damage.

  ●  Products purchased ex-showroom display.

What to do if something goes wrong

If  your  product  does  not  work  correctly  refer  to  this 

manual for fault diagnosis and check that it is installed 

and commissioned in accordance with our instructions.

If this does not resolve the issue, contact us for help 

and advice.

Extended Guarantees

A selection of protection plans are available that 

enable you to cover repair bills (excludes Eire). Ring 

01922 471763 for more details.

01 531 9337

Mira Customer Services Dept, Cromwell 

Road, Cheltenham, Gloucestershire, GL52 

5EP

Helpdesk  Service

  -  Ring  our  Customer 

Services Team for product advice, to purchase 

spare parts or accessories or to set up service 

visit. You can contact us via phone or e-mail, 

details  below.  Please  provide  your  model 

name,  power  rating  (if  applicable)  and  date 
of purchase.

Mira Showers Website (www.mirashowers.

co.uk)

Visit  our  website  to  register  your  guarantee, 

download  user  guides,  diagnose  faults, 

purchase  our  full  range  of  accessories  and 
popular spares, or request a service visit.

Spares and Accessories

 - We hold the largest 

stocks of genuine Mira spares and accessories. 

Contact us for a price or visit our website to 

purchase items from our accessory range and 
popular spares

Service/Repairs -

 No one knows our products 

better  than  our  nationwide  team  of  Service 

Technicians. We can carry out service or repair 

work to your product both during and after the 

guarantee  period. Ask  about  our  fi xed  price 

service repairs.

To Contact Us: UK

CUSTOMER SERVICE

E-mail: Visit 

www.mirashowers.co.uk/

contactus

To Contact Us: Eire Only

0844 571 5000

Fax: 01242 282595

E-mail: CustomerServiceEire@

mirashowers.com

Summary of Contents for Mira Sport Thermostatic

Page 1: ...1 These instructions must be left with the user Installation Guide Mira Sport Thermostatic 9 0 9 8 kW For SPARES ADVICE or REPAIRS Please call us on 0844 571 5000 UK Only...

Page 2: ...selection and for temperature flow adjustment A unique flow regulator stabilises any temperature changes caused by water pressure fluctuations which can result from taps being turned on or off or toil...

Page 3: ...at the water in the shower is frozen 6 DO NOT switch the shower on if water starts leaking from the shower case Isolate the electrical supply to the shower immediately 7 DO NOT connect the outlet of t...

Page 4: ...elf with the part names and to confirm that the parts are included 1 x Mira Sport Thermostatic Electric Shower 3 x Wall Plugs 1 x Compression Nut 3 x Fixing Screws 1 x Olive 1 x Installation Guide 1 x...

Page 5: ...TOR TERMINAL BLOCK HEATER TANK MICRO SWITCH L MICRO SWITCH R SOLENOID LED LED HOUSING PUSH BUTTON SWITCH BROWN B GREEN D BLUE C RED K BROWN J BROWN G BLACK M BLACK L RED H BLUE E BROWN F B L U E E BLA...

Page 6: ...Minimum Static Pressure 20 kPa 0 2 bar Maximum Static Pressure 1000 kPa 10 bar Maximum Inlet Temperature 30 C Minimum Inlet Temperature 2 C Inlet Connection 1 2 BSP Male 15 mm Compression Fitting Maxi...

Page 7: ...on within the shower area and is fitted with a pressure relief valve It must be positioned over a water catchment area with the controls at a convenient height for the user 6 The shower must be fitted...

Page 8: ...ctions caused by excessive limescale formation are not covered by this shower s guarantee see back page for details 17 The installation must not cause the hose to be sharply kinked during normal use 1...

Page 9: ...ins system A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must...

Page 10: ...move the service tunnel Using the installation template supplied mark the positions of the three fixing holes Note Ensure that there are sufficient lengths of supply pipe and electrical cable to reach...

Page 11: ...shower from the top or rising entering the shower from the bottom NOTE DO NOT use an incoming supply entering the shower directly from the back Add an elbow to the supply pipe and connect it as a risi...

Page 12: ...connections and back case are not under any stress due to misaligned pipework or electrical cables Terminal Block Outlet Connector Cold Water Supply Pipe Inlet Connector Strip back sufficient outer c...

Page 13: ...ervice tunnel Ensure the control dials are aligned with the spindles and replace the cover Tighten the three cover screws 16 17 18 19 20 21 Do not use alternative screws to secure the cover This can c...

Page 14: ...rise slightly 7 5 10 secs COLD HOT LOW HIGH ECO POWER Turn power control to High Temperature will rise further Adjust temperature as required Flow rate will adjust automatically Push START STOP button...

Page 15: ...rical supply via the pullcord or wall mounted switch Renew the fuse or reset the MCB RCD If fault persists contact your installer Check case inserts are cut and fitted correctly Check services electri...

Page 16: ...ead blocked Hose kinked or blocked Other outlets e g Toilet garden hose washing machine etc drawing water while the shower is being used Flush supply pipe Clean inlet filter Contact local water compan...

Page 17: ...tch faulty Replace as necessary Shower fails to produce hot water when set on Eco High setting ON ECO HIGH Insufficient water supply Possible failure of the microswitch or thermal switch Contact local...

Page 18: ...se washer for further use Remove the three screws that hold the cover on the shower and remove the cover Remove the service tunnel from the shower Use a suitable spanner to remove the filter from the...

Page 19: ...roswitch 2 pin 1563 536 Control Belt 1746 458 9 0kW 1746 459 9 8kW Heater Tank 1563 719 Thermal Switch 1746 461 Outlet Connector 1746 446 Switch LED Assembly 416 51 Coil 416 38 Inlet Clamp 1563 540 In...

Page 20: ...product or consequential loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or replace...

Page 21: ...Pdf Supplied By http www plumbworld co uk...