SPARE PARTS

1746.460

Cover

B

B

A

A

B

A

1563.522 

Cover Seal -  not shown

 

1563.541

 Screw Pack - identified 

'A'

1746.456

 Component Pack - identified 

'B'

A

A

872.01

Microswitch

(2 pin)

1563.536

Control Belt

1746.458 (9.0kW)
1746.459 (9.8kW)

Heater Tank

1563.719

Thermal Switch

1746.461

Outlet 

Connector

1746.446

Switch / LED 

Assembly

416.51

Coil

416.38

Inlet Clamp

1563.540

Inlet Valve

1563.538

Temp Cam 
& Pulley

1746.449

Terminal 
Block

A

1746.444

Switch 

Assembly

1829.062

Inlet Filter

1829.063

Inlet 
Connector

1746.448

Service Tunnel

Summary of Contents for Mira Sport Thermostatic

Page 1: ...1 These instructions must be left with the user Installation Guide Mira Sport Thermostatic 9 0 9 8 kW For SPARES ADVICE or REPAIRS Please call us on 0844 571 5000 UK Only...

Page 2: ...selection and for temperature flow adjustment A unique flow regulator stabilises any temperature changes caused by water pressure fluctuations which can result from taps being turned on or off or toil...

Page 3: ...at the water in the shower is frozen 6 DO NOT switch the shower on if water starts leaking from the shower case Isolate the electrical supply to the shower immediately 7 DO NOT connect the outlet of t...

Page 4: ...elf with the part names and to confirm that the parts are included 1 x Mira Sport Thermostatic Electric Shower 3 x Wall Plugs 1 x Compression Nut 3 x Fixing Screws 1 x Olive 1 x Installation Guide 1 x...

Page 5: ...TOR TERMINAL BLOCK HEATER TANK MICRO SWITCH L MICRO SWITCH R SOLENOID LED LED HOUSING PUSH BUTTON SWITCH BROWN B GREEN D BLUE C RED K BROWN J BROWN G BLACK M BLACK L RED H BLUE E BROWN F B L U E E BLA...

Page 6: ...Minimum Static Pressure 20 kPa 0 2 bar Maximum Static Pressure 1000 kPa 10 bar Maximum Inlet Temperature 30 C Minimum Inlet Temperature 2 C Inlet Connection 1 2 BSP Male 15 mm Compression Fitting Maxi...

Page 7: ...on within the shower area and is fitted with a pressure relief valve It must be positioned over a water catchment area with the controls at a convenient height for the user 6 The shower must be fitted...

Page 8: ...ctions caused by excessive limescale formation are not covered by this shower s guarantee see back page for details 17 The installation must not cause the hose to be sharply kinked during normal use 1...

Page 9: ...ins system A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must...

Page 10: ...move the service tunnel Using the installation template supplied mark the positions of the three fixing holes Note Ensure that there are sufficient lengths of supply pipe and electrical cable to reach...

Page 11: ...shower from the top or rising entering the shower from the bottom NOTE DO NOT use an incoming supply entering the shower directly from the back Add an elbow to the supply pipe and connect it as a risi...

Page 12: ...connections and back case are not under any stress due to misaligned pipework or electrical cables Terminal Block Outlet Connector Cold Water Supply Pipe Inlet Connector Strip back sufficient outer c...

Page 13: ...ervice tunnel Ensure the control dials are aligned with the spindles and replace the cover Tighten the three cover screws 16 17 18 19 20 21 Do not use alternative screws to secure the cover This can c...

Page 14: ...rise slightly 7 5 10 secs COLD HOT LOW HIGH ECO POWER Turn power control to High Temperature will rise further Adjust temperature as required Flow rate will adjust automatically Push START STOP button...

Page 15: ...rical supply via the pullcord or wall mounted switch Renew the fuse or reset the MCB RCD If fault persists contact your installer Check case inserts are cut and fitted correctly Check services electri...

Page 16: ...ead blocked Hose kinked or blocked Other outlets e g Toilet garden hose washing machine etc drawing water while the shower is being used Flush supply pipe Clean inlet filter Contact local water compan...

Page 17: ...tch faulty Replace as necessary Shower fails to produce hot water when set on Eco High setting ON ECO HIGH Insufficient water supply Possible failure of the microswitch or thermal switch Contact local...

Page 18: ...se washer for further use Remove the three screws that hold the cover on the shower and remove the cover Remove the service tunnel from the shower Use a suitable spanner to remove the filter from the...

Page 19: ...roswitch 2 pin 1563 536 Control Belt 1746 458 9 0kW 1746 459 9 8kW Heater Tank 1563 719 Thermal Switch 1746 461 Outlet Connector 1746 446 Switch LED Assembly 416 51 Coil 416 38 Inlet Clamp 1563 540 In...

Page 20: ...product or consequential loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or replace...

Page 21: ...Pdf Supplied By http www plumbworld co uk...

Reviews: