27
1490289-W2-A
Servicing
WARNING
There are no user serviceable parts inside the shower. Servicing of the shower
must only be carried out by qualified, competent personnel following the
instructions provided in this guide and those provided with any spare part.
Before replacing any parts, ensure that the underlying cause of the malfunction
has been resolved.
Cleaning the Inlet Filter
Warning! Isolate the electrical and water supplies before removing the cover.
Remove the cover.
Remove the elbow from the inlet connector.
Note:
Depending on your installation it may
be necessary to remove the shower from the
wall to allow filter removal.
In this case isolate all supplies and follow steps
6 - 8 in reverse order as detailed in section:
‘INSTALLATION’
.
Inlet Filter
Inlet
Connector
Prise the filter from the inlet connector
assembly.
Rinse the filter under a running tap to remove
any lodged particles. If necessary, use a kettle
descalent in accordance with the manufacturer’s
instructions. Refit the inlet filter and follow
steps 7 and 10 as described in section:
‘INSTALLATION’.
Note:
If the shower was removed from the wall, steps 6, 7, 8 and 10 will need to be
followed as described in section:
‘INSTALLATION’.
Follow the steps detailed in section:
‘COMMISSIONING’
to prepare the shower for
use.