15
1490289-W2-A
Secure the shower to the wall with fixing screws and wall plugs (supplied) or
appropriate wall fixings for your installation.
Thoroughly flush the supply pipe.
Inlet
Supply
Pushfit
Elbow
Inlet Connector
Connect the inlet supply pipe to the inlet connector
using a push fit elbow or an elbow with compression
nuts and olives.
Important!
Do Not use pushfit elbows that require
specialist tools for removal. Access to the inlet filter
is required periodically and so any connector needs
to be easily removed for maintenance.
Note!
When making connections to the shower. Do
not use jointing paste products as damage to the
shower will occur.
Turn on the water supply and check connection for
leaks.
L
(Live) = Brown wire
(Protective Earth) =
Green / Yellow sleeved wire
N
(Neutral) = Blue wire
Terminal
Block (LH)
Terminal
Block (RH)
Terminal Blocks are provided on both the left
and right for convenience. Use the terminal
block location that is most appropriate for
your installation i.e. If the electric supply is
on the right hand side then use the right
hand terminal block.
Strip back sufficient outer cable insulation to
enable routing to the terminal block.
Fit an earth sleeve to the earth wire.
Insert the wires into the terminal block.
Tighten the screws in the terminal block,
ensure the wires are secure and tight.
Ensure the earth bonding complies
with relevant regulations.