1.
The product must not be installed in an area where it may freeze. Pipework to the product
that could become frozen must be properly insulated.
2.
Do not install the product in a position in which service access is restricted.
3.
For stud partitions alternative fixings may be required.
4.
Isolating valves must be installed close to the product for ease of maintenance.
5.
Pipework must be rigidly supported and avoid any strain on the connections.
6.
Pipework dead-legs should be kept to a minimum.
7.
If pipework enters the product from the rear through a hole in the wall, provision must
be made to prevent water ingress back into the wall structure.
8.
The position of the shower and shower fittings must provide a minimum gap of 25 mm
between the showerhead and the spill over level of any bath, shower tray or basin and
a minimum gap of 30 mm between the showerhead and the spill over level of any toilet,
bidet or other appliance with a Fluid Category 5 backflow risk (see diagram).
General
Installation must be carried out in accordance with these instructions, and must be conducted
by designated, qualified and competent personnel.
The installation must comply with the “Water Supply Regulations 1999 (Water Fittings)” or any
particular regulations and practices, specified by the local water company or water undertakers.
Note!
Make sure that all site requirements correspond to the information given in section:
‘Specifications’
.
Zone of
Backflow Risk
Toilet or Bidet
FC5
Hand Basin
FC3
Bath or Shower
Tray FC3
Mixer Shower
25 mm
Minimum
25 mm
Minimum
9.
The showerhead should be positioned
so that it discharges down the centre
line of the bath or across the opening
of a shower cubicle.
10.
Only use the inlet connections supplied
with the product.
DO NOT
use any
other type of fittings.
11.
All pipework must be checked for
leaks before the product installation
is completed. The product should
be pressurised & the inlet & outlet
connections inspected.
12. DO NOT
overtighten connections,
screws or grubscrews as product
damage may occur.
13.
Upon completion of installation, or if the
product is dismantled during installation
or servicing, then the product must be
inspected to ensure that there are no
leaks.
30 mm
Minimum
14.
Having completed the installation, make sure that the user is familiar with the operation
of the product.