7
1232447-W2-A
Installation of the Bar Valve
Offset
Connector
Support Bracket
½" BSP Female
Connection
Apply Silicone
Sealant to seal
hole in wall
40 - 43 mm
The thermostatic bar valve should be installed where it will be supported by fixed pipework.
1.
Install the pipework, making sure that it is set at the correct distance apart (150 ± 24 mm)
and solidly fixed
.
2.
Apply suitable thread sealant (not supplied) and attach the offset connectors to the
pipework in the wall. The offset connectors must protrude between 40 and 43 mm from
the finished wall.
Note!
Connections are:
Hot-Left
,
Cold-Right
. This is very important as this product
does not allow for reversed inlets.
Tighten the offset connectors using a suitable
spanner. Make sure that the connectors are
level and set at the correct distance apart,
using the bar valve as a guide to spacing.
Caution!
Make sure that the supply pipework
is flushed before installing the Bar Valve.
Assemble the bar valve with a sealing
washer/filter in each inlet and attach to the
offset connectors.
Note!
Connections are:
Hot-Left
,
Cold-Right
.
Screw the concealing plates onto the offset
connectors until they come into contact with
the wall.
Spanner Flats
Tile
150 mm
Important! Before installing the pipework, please ensure that there is a minimum of
1065mm height clearance to allow for the rigid riser and overhead to be installed above.
If installing in a restricted height area, a shorter riser rail can be ordered as a spare part.
1
2
3
4