5
INFORMATION
ABOUT MAINTENANCE
EN
38
5.5
Air filter check
Important
•
Before proceeding with operation, read
•
When the cartridge
G
is dirty, do not clean it but
replace cartridges
B and G.
NOTE:
Components not necessarily supplied by
KOHLER
.
1.
Release the two clasps
F
of the cover
A
.
2.
Remove the cartridges
B and G
.
3.
Clean the inside components
A and D
with a damp
cloth.
4.
Do not use compressed air
, repeatedly tap the front
side
E
on a flat surface.
5.
Reinstall:
- cartridges
G and B.
- the cover
A
checking the right tightness of clasps
F
.
Fig 5.5
5.6
Check of the radiator heat - exchanger surface
Danger
•
For safety precautions see
NOTE:
Component not necessarily supplied by
KOHLER
.
Important
•
Before proceeding with operation, read
•
Wear safety goggles when using compressed air.
•
The radiator heat-exchange surface must be cleaned
on both.
1.
Check the radiator heat-exchange surface
D
.
2.
Clean the surface with a brush soaked in special
detergent if it is clogged.
Fig 5.6