INFORMATION
ABOUT USE
4
33
EN
Warning
•
Forced regenerations must only be executed if required by the ECU when the "HIGH SOOT"
warning light goes on (due to a Level 3 - 5 particulate accumulation).
•
Do NOT execute the forced regenerations if not required by the ECU (due to a Level 0 - 2
particulate accumulation).
•
Repeated forced regenerations cause significant engine oil contamination by the fuel.
•
The operations described in Par. 5.3 or 5.4 must be executed after every forced regeneration.
•
If the regeneration inhibition function is misused, the particulate accumulation level will increase
within a short time.
•
The engine oil filter and oil must be changed after a Service Regeneration is completed via
KOHLER software
•
(Level 5 Particulate accumulation).
•
Fuel contamination allowed in the engine oil is 3% MAX.
•
Any engine load must be eliminated during forced regeneration so as to prevent damaging the
ATS *2 system.
•
Do not switch the engine off during level 3, 4 and 5 regeneration so as to prevent damaging the
ATS system.