6. Prepare the Cables
IMPORTANT!
The cables that will connect the control amplifier to the bath transducers, chromatherapy
control (if equipped), and the user interface are each 25’ (7.6 m) in length. Plan the location of the control
amplifier so these cables, when routed and connected, will easily reach without placing tension on the
cables.
NOTE:
The heated surface control is mounted to the board at the end of the bath.
Connect the larger Ethernet end of the user interface cable to one of the two ports on the heated
surface control.
Connect the inter-connect cable (both ends are Ethernet) for the amplifier to the open port on the
heated surface control.
Carefully cut the cable tie securing the coiled transducer wires to the back of the bath.
Bind all electrical cables together to allow for easier routing through the shroud.
Inter-Connect
Cable
User Interface Cable
Heated
Surface
Control
User Interface
Transducer Wires
Control Board
Inter-Connect
Cable
Heated Surface
Control
Chromatherapy
Cable (If Equipped)
Optional Auxiliary-In
Cable
Drip
Loop
Kohler Co.
11
1237790-2-D
Summary of Contents for K-2593-VBW-0
Page 65: ...1237790 2 D...
Page 66: ...1237790 2 D...
Page 67: ...1237790 2 D...
Page 68: ...USA Canada 1 800 4KOHLER M xico 001 800 456 4537 kohler com 2017 Kohler Co 1237790 2 D...