background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 1 of 25

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2018 Jason International, Inc.

Copyright © 2018 Jason International, Inc.

“TO BE REMOVED FOR USE BY THE OCCUPANT.”

49-1020-000

Date   08/2018

OWNER’S MANUAL

forma

®

 and Designer Collection Baths 

INSTALLATION, OPERATION, AND MAINTENANCE

Jason International, Inc.

8328 MacArthur Drive

North Little Rock, AR 72118
www.jasoninternational.com

MADE IN THE U.S.A.

 

OWNER’S RECORD

Dealer: 

Date Purchased: 

Date Installed: 

Installer: 

PLACE SERIAL NUMBER CARD WITH 

PRODUCT CONFIGURATION IN THIS BOX

INSPECTION

Inspect the unit prior to installation.  In the event of a 

problem, DO NOT install the unit.

All components are factory assembled to the bath and the 

unit is water tested and inspected prior to leaving Jason 

International, Inc.

NOTE: Transportation and insurance from Jason’s 

factory are the buyer’s responsibility.

Damage sustained in transit is the responsibility of 

the carrier.

  If damage is discovered, the carrier must 

be immediately notified in writing with a request for a 

representative to inspect the unit.  Failure of the carrier 

to respond should be reported to the seller and carrier.  

Always file a freight claim promptly.

The installer is responsible for insuring that the unit is 

free from defects or shipping damage.  

In the event of a 

problem, DO NOT install the unit.

Jason International is not responsible for damage that 

might have been avoided by inspection or testing prior to 

installation.

Damage to the unit during installation will not be covered 

by warranty and is the responsibility of the installer.

If the carton shows sign of damage, inspect 
the product before accepting and describe the 
problem on the Bill of Lading.

ALL WARRANTY CLAIMS ON ACRYLIC SURFACE 

DAMAGE MUST BE MADE PRIOR TO INSTALLATION. 

Inspect plumbing and bath surface for missing or damaged 

components. Alert your dealer of any discrepancies. 

To protect the unit from damage keep the bath in the 

carton until ready for installation.

EQUIPMENT ACCESS

In accordance with Building Codes, service access to 

all hydrotherapy bath equipment, controls and electrical 

connections must be provided during installation 

(Recommended minimum 28” x 17” [71 x 43 cm]). 

Insufficient access will hinder repair and maintenance. 

Warranty service will not cover costs of providing 

equipment access.

The Specification Sheet for this bath contains additional 

technical information.  This sheet can be provided by your 

dealer or accessed online at www.jasoninternational.com.

Summary of Contents for AirMasseur

Page 1: ...and carrier Always file a freight claim promptly The installer is responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason...

Page 2: ...l anticoagulants stimulants antihistamines vasoconstric tors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and f...

Page 3: ...plus de 10 15 minutes et pour les jeunes enfants F Puisque les temp ratures excessives ont un potentiel lev pour les f tus durant les premiers mois de la grossesse les femmes enceintes ou possiblement...

Page 4: ...la garantie du fabricant DANGER Ne pas modifier le c blage install en usine Tous les mat riaux de construction et c blage doivent tre loign s de toutes sources de chaleur moduites par le abin ATTENTIO...

Page 5: ...r to the Trouble Shooting Guide section of this manual If the unit still fails to operate and is out of warranty contact an authorized service technician for repair If the unit is within the warranty...

Page 6: ...low water tem perature sensors and Jason s Bluetooth Sound Immersion system WHIRLPOOL FEATURES Jason s Whirlpool hydrotherapy bath utilizes Perfect Pres sure Perfect Flow jets that are directed at ke...

Page 7: ...CONTROLS AND OPERATING INSTRUCTIONS cont STANDARD PREMIER EDITION ELECTRONIC CONTROLS ICONS POWER Icon WHIRLPOOL Icon AIRMASSEUR Icon MICROSILK Icon LED Icon Premier Signature PILLOW Icon Optional Bl...

Page 8: ...e will start with the next press indicated by a rapid flash of the icon Pressing the icon again will turn the neck jets OFF and the icon will turn WHITE Once the system returns to Standby mode the ico...

Page 9: ...minutes the blower will turn on for two 2 minutes to allow the plumbing lines to drain This will be indicated by the AIRMASSEUR icon turning solid GREEN This purge cycle can be canceled by pressing an...

Page 10: ...c FEATURES CONTROLS AND OPERATING INSTRUCTIONS cont SIGNATURE EDITION ELECTRONIC CONTROLS ICONS WHIRLPOOL Icon AIRMASSEUR Icon MICROSILK Icon PILLOW Icon Optional Blower SPEED Icon LED Icon Premier Si...

Page 11: ...PEED icon to change an option For example press and release the AIRMASSEUR icon to change from Product Test to the Temperature option Press and release the SPEED icon to change the temperature display...

Page 12: ...g lines to drain The AIRMASSEUR icon is used to activate the blower and the 20 minute timer CONSTANT Mode will start with the first press and CONST AIR will be displayed WAVE Mode will start with the...

Page 13: ...s Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e No vus Plastic Polish No...

Page 14: ...level on top of the deck on both ends and front of the bath Jason baths are designed to be support ed at the base of the bath If the floor is smooth and level the bath s Level Form Base will provide...

Page 15: ...ath is positioned in the area of intended installa tion cut the equipment support strap s to allow the equip ment to rest firmly level with the bottom of the bath on the floor We recommend securing th...

Page 16: ...t of the bath Choose a loca tion as close as possible to the bath to ensure maximum efficiency 1 The installer must determine the layout of the pip ing exact remote mount location and service ac cess...

Page 17: ...lectrical equipment and exposed metal in the area as may be required by local code Note The air blower s exterior housing is made of all plastic ma terials and does not require a bonding conductor Gro...

Page 18: ...Cable CBL 366 LED Cable CBL 366 Keypad Cable CBL 372 MS Pump 1 2 J SON t d dt h K D d s W D E D E D W TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Optional Bluetooth Sound Immersion Transducers...

Page 19: ...A9a Gincmi Pinc Mloi Drooidvlrot Prv Vtie LED Cable CBL 366 LED Cable CBL 366 Keypad Cable CBL 372 Mrce 1 Ncmi Pinc Mloi Drooidvlro Cmrzis 1 2 Keypad IDU 264 J SON Ozone D d s W D E h t d dt D E K TRA...

Page 20: ...ldi Heater 1 2 J SON t d dt h K D d s W D E tW W D E d s W D E TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Optional Bluetooth Sound Immersion Transducers installed on bath Bluetooth amp supplie...

Page 21: ...9a Gincmi Pinc Mloi Drooidvlrot Ozone Ncmi Pinc Mloi Drooidvlro LED Cable CBL 366 LED Cable CBL 366 Keypad Cable CBL 372 1 2 Ncmi Pinc Mloi Drooidvlro Cmrzis MS Pump Keypad IDU 264 J SON D D E s d W E...

Page 22: ...nc Mloi Drooidvlro MS Pump Keypad IDU 264 J SON h D t d dt D E s d W E K D E tW W D E d s W D W TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Optional Bluetooth Sound Immersion Transducers instal...

Page 23: ...lro Vr Eieldcvie 120 60I 20B HGDL Ssrvidvie Tiswldi Heater 1 2 Ncmi Pinc Mloi Drooidvlro Cmrzis Keypad IDU 264 J SON D t d dt D E s d W E h K D E tW W D E d s W Standard Edition Premier Edition Signat...

Page 24: ...rted into the control box outlet c Check and reconnect if necessary Equipment does not manually shut off a Control defective a Refer to installer dealer Equipment shuts off by itself or before set tim...

Page 25: ...y validation card The pre addressed warranty registration card MUST be filled out by the purchaser within thirty 30 days from purchase and mailed to Jason International Inc in order for the limited wa...