9. Install the Control Amplifier
WARNING: Risk of electric shock.
Connect the control amplifier to a properly grounded,
grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual
Current Device (RCD). Do not remove the grounding pin from the plug or use a grounding adapter.
IMPORTANT!
Keep insulating materials away from the control amplifier. Provide an unobstructed air
space around the control amplifier to permit cooling.
NOTE: Do not
remove the mounting brackets from the control amplifier.
Position the control amplifier flush or recessed from the front of the studs.
Using the wood screws provided, secure the control amplifier to the framing. Use the anchors
provided if securing to a wall material other than wood.
NOTE:
To make wiring connections more accessible, temporarily secure the control amplifier with one
screw on each side to allow the control amplifier to tilt forward. Once wiring connections are made, secure
the control amplifier with the remaining screws.
Remove the cover from the control amplifier by removing the four screws. Retain for reinstallation.
NOTE:
The transducer terminals and wires are numbered to identify the correct connections. When
required, the control amplifier can be removed to aid in the wire connection process.
Securely
attach the transducer wires to the transducer terminals on the control amplifier. The white
with black wires are the positive (+) leads.
If equipped, connect the chromatherapy connector to the chromatherapy terminal on the control
amplifier.
Connect the inter-connect cable from the control box to the amplifier.
If used, connect the auxiliary-in RCA connectors to the auxiliary-in connections on the control
amplifier.
Reinstall the cover to the control amplifier with the four screws.
Plug the control amplifier into the electrical outlet.
Plug the junction box cord into the electrical outlet.
Auxiliary In
Chromatherapy
(Some Models)
Inter-Connect
Cable
Screws
Alternate Holes
Transducer Wiring
Screws
Cover
Grounded Outlet
Experience
Data Module
Control
Amplifier