Troubleshooting (cont.)
Heated Surface Troubleshooting Table
Symptoms
Probable Cause
Recommended Action
2.
Bath is on, but there is
little or no heat.
A.
Heater cable loose or damaged.
A.
Inspect the cables between the user
interface, heated surface control,
and control amplifier. Secure
connections or replace cables as
needed.
B.
Heater/insulation loose on the
bath.
B.
Secure the heater/insulation to the
bath.
C.
Heat indicator is set to low heat.
C.
Press the plus [+] icon to increase
temperature.
D.
Heater does not work.
D.
Replace the heater.
E.
Temperature sensor does not
work.
E.
Replace the heater.