INSTALLATION INSTRUCTIONS
791033-100 Rev. I
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
AMERICAST BRAND
ENGINEERED MATERIAL
CAMBRIDGE™
WHIRLPOOL/BATHING POOL
2460.XXXW SERIES
2461.XXXW SERIES
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
1-1/2 N.P.T. THREADS
1-1/2 O.D. TAILPIECE
441mm
(17-3/8)
70mm
(2-3/4)
117mm
(4-5/8)
ROUGH
FLOOR
102mm
(4)
451mm
(17-3/4)
24mm
(15/16)
406mm
(16)
OPTIONAL
TO FLOOR
USUALLY
BETWEEN
1651 & 1981mm
(65 & 78)
711mm
(28)
C/L OF CURTAIN ROD
USUALLY 1930mm(76) FROM
FINISHED FLOOR
C/L OF
VALVES
102mm
(4)
102mm
(4)
SPOUT-
1/2 N.P.T.
FINISHED
WALL
SHOWER ARM- 1/2 N.P.T.
32mm(1-1/4) DIA. HOLE
SEE
NOTE
■
76mm
(3)
813mm
(32)
1524mm
(60)
19mm
(3/4)
70mm
(2-3/4)
203mm
(8)
FINISHED
WALL
102mm
(4)
102mm
(4)
C/L OF 1/2
SUPPLIES
AS REQ'D
C/L OF
DRAIN
229mm x 305mm
(9 x 12)
FLOOR
CUTOUT
PUMP
406mm
(16)
PROVIDE ACCESS TO PUMP FOR
SERVICING ON ALL INSTALLATIONS
ON / OFF
SWITCH
64mm
(2-1/2)
25mm
(1)
(2) 54mm(2-1/8)
DIA. HOLES
60mm 13mm
+
(2-3/8) (1/2)
+
GENERAL SPECIFICATIONS FOR 2460/2461 WHIRLPOOL
WHIRLPOOL ELECTRICAL SPECIFICATIONS
SYSTEM I PUMP
SAFETY HEATER
1.6 HP, 9.7 AMPS,120V.
12 AMPS, 120V.
60 x 32 x 17-3/4 In. (1524 x 813 x 451mm)
190 Lbs. (86 Kg.)
607 Lbs. (273 Kg.)
50 Gal. (190 L)
39 Gal. (148 L)
41 x 20 In. (1041 x 508mm)
54 x 26 In. (1372 x 660mm)
14 In. (356mm)
46 Lbs./Sq.Ft. (220 Kgs./Sq.m)
15.6
31.5
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
T H A N K Y O U . . .
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
* see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470*
• Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 4
Stringers
• Drop Cloth
• 15 amp GFCI
Outlet
• Cement, Plaster,
Grout
SAFE-T-HEATER
REMOVABLE BLANK