ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

BLACK

WHITE

1 2 0   V A C

G N D .

S E P A R A T E   1 5   A M P

G F C I   O U T L E T

W H I R L P O O L   M O U N T E D

A I R   S W I T C H   o r

W A L L   T I M E R  

E L E C T R I C A L   I N S T A L L A T I O N

P U M P / M O T O R

ELECTRICAL INSTALLATION INSTRUCTIONS

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other 
applicable codes.

WARNING:

When using electrical products, basic precautions should always be observed, including the following:

1. DANGER:  RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a ground-fault circuit interrupter.

2. Grounding is required.  The unit should be installed by a licensed electrician and grounded.

3. Install to permit access for servicing.

4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
 

The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit.  The circuit should be hard-wired from the 
electrical power supply panel.  The circuit must be a three (3) wire circuit from the electrical supply panel.  A grounded 
neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE 
15 AMP MAXIMUM GFCI CIRCUIT.