background image

1374956-T01-B

-17-

Regularly remove dirt inside the drain cover. It is recommended 

to clean every month.

Drain Cover Assembly

Јࡊतুў

Drain Cover Assembly

Јࡊतুў

IMPORTANT CONSUMER INFORMATION

1.  Safety warning: In order to ensure safety, this product shall 

be grounded reliably. It is forbidden to use this product 
without reliable grounding. Make sure that the live wire and 
neutral wire are connected properly.

2.  When AC power unit is connected to 220V AC power 

supply, corresponding protective measures should be 
taken.

3. 

Please confirm no water penetration at the connection 

area of AC wire, and the connection area is not easy to be 
affected by damp. 

4.  The head AC power supply must be protected with 

appropriate fuse.

5. 

Please confirm the AC power supply should be shut off 

before maintaining the products with AC power related.

6.  All electrical connection must be compliance with related 

regulation and codes.

7.  All installation staff should be well familiar with installation 

instruction.

8.  The hose must use the attached hose. Do not use the old 

hose.

9.  If the water pressure is too high, increase the relief valve.
10. The ambient temperature of the product shall be higher 

than freezing temperature.

11. The inlet water quality shall be municipal tap water which 

complies with GB5749.

12. Do not pour water into the air outlet.
13. The blockage shall be immediately cleaned up.
14. Do not block the water outlet.

Note: Troubleshooting needs to be done by professional of 
KOHLER CHINA. Users are not suggested to do this without 
help. Please remember that the checking and repairs done by 
users themselves could easily cause damage to the machine or 
cause physical harm to the person.

 

需定期对下水盖内部污垢进行清洗,建议每月进行。

 

用户须知

1. 

安全警示:为确保安全,产品需进行可靠接地,严禁在无可
靠接地的情况下使用本产品。需确保火线、零线对接正确,
不得接反。

 

2. 

将产品接入

220V

电源时,应采取相应的保护措施。

 

 

3. 

应确保交流导线连接处无水渗入以及不易受潮。

 

 

4. 

交流电的总电源必须有合适的熔断丝加以保护。

 

5. 

维修交流供电型的产品时,必须首先断开交流电源。

 

6. 

所有电路连接必须符合相关规范和条例要求。

 

7. 

所有参与安装人员都必须熟知安装说明。

 

8. 

进水软管只能用附带软管,旧软管不能使用。

 

9. 

如果水压过高,需增加减压阀。

10. 

产品使用环境需高于结冰温度。

 

11. 

本产品进水水质为符合

GB5749

的市政自来水。

 

12. 

不得往出风口灌水。

13. 

堵塞物需要及时清理干净。

14. 

不得堵塞出水口。

注意:本产品需由本公司专业人员维修,用户在没有任何技术协
助下修理机器,易导致零件损坏或人身伤害。

Summary of Contents for K-23984T-0

Page 1: ...structions and Homeowners Guide 安装说明及用户手册 KOHLER CHINA INVESTMENT CO LTD NO 158 JIANG CHANG SAN ROAD JING AN DISTRICT SHANGHAI PRC POST CODE 200436 科勒 中国 投资有限公司 上海市静安区江场三路 158 号 邮编 200436 Waterfoil Lavatory Wall Hung 沃弗多功能净洗干手器 K 23984T 0 Waterfoil Lavatory Wall Hung IoT 沃弗多功能净洗干手器 云智能版 K 23984T X 0 ...

Page 2: ...ular installation This will help you avoid costly mistakes In addition to proper installation read all operation and safety instructions All information in these instructions is based upon the latest product information available at the time of publication Kohler China reserves the right to make changes in product characteristics packaging or availability at any time without notice These instructi...

Page 3: ... Frequency 电压 频率 220V 50Hz Rated Input Power 额定输入功率 1400W Fan Power 风机功率 650W Heating Power 加热功率 750W Ingress Protection 防护等级 IP24 尺寸图 Unit mm 单位 毫米 规格 Note The error range of the above parameters shall meet the national standards 注 以上参数允许误差范围按国标执行 Kohler reserves the right to change marked dimensions without prior notice 科勒公司保留随时变更图中标示尺寸的权利 无需另行通知 ...

Page 4: ...he diagram is for reference only The product may differ from the diagram 注 示意图仅供参考 具体以实物为准 WIRING DIAGRAM Heating Wire Assembly ऄࢽВুў BLDC Assembly BLDCুў BLDC Driver Board BLDC Ԉߡ Display Board ުॐߡ Keypad ܷ ߡ Main Control Panel П ߡݏ Overflow ࡊ Soap High 䤞䃠 Soap Low 䤞䃠Ѻ PWM Speed Governing PWMલବ Speed Feedback ବՆ Opto couplers Isolation Ұ凥ஜख़ L Live Wire ࢮি 220V 50Hz 10A N Neutral Wire னি 220V 50Hz...

Page 5: ...ढ 4 Ø10 hole depth 60 Drill the hole after laying the wall tiles 4 Ø10 ࢋ 60 ૉ ृ ե۸ Embedded junction box ⷃ ݎ িढ Inlet angle valve position ࡊઅஂѹ Required inner diameter of drain assembly hole is Ø40 45 ߔ Սӄ ڬ ࡌØ40 45 Floor tile position ߡृѹ ԥӒࡊङ ⷃॐ Embedment Diagram cold water only Embedment Diagram hot and cold water ߄Ӓࢽࡊङ ⷃॐ Note It needs to decide the finish position of floor tiles ࡨ үؔӟ ߡृவ ۨѹ ...

Page 6: ...tact our after sales department in time Packing List Key ୗ Cabinet ыଭी ѽ Top Cover ыଭीЇՖவ Waterfoil Lavatory Wall Hung Unit ߑѽুў Drain Assembly ুߔ ў M8 Sleeve Anchor 升剱夊ߺুў M8 Bolt M8夊ߺ M8 Sleeve M8 M8 Washer M8 ֻٵ M8 Spring Washer M8 ֻڟ M8 Nut M8夊 Soap Bottle Assembly Wall Hung ো䤞ࣼুў 2 M5 Screw 2 M5夊 2 C Clip 2 C צ C Clip Package C ֺ צ ԕ Hose ࡊ Hose ࡊ Thermostatic Valve ஂ ۉ ...

Page 7: ... be splashed Safety warning The embedded line of the junction box shall be connected to the fixed wiring power grid and equipped with an earth leakage protection air switch for the protection against moisture and earth leakage Make sure that the incoming tap water pressure is not less than 0 2MPa and its maximum pressure is not more than 0 8MPa According to the depth of the drain assembly hole cut ...

Page 8: ...ޅ ե୧ব夊 Waterfoil Lavatory Wall Hung Unit ߑѽুў M8 Sleeve Anchor 升剱夊ߺুў Wall ѽ Measure the bracket with a level ruler to ensure that the entire product is in a horizontal position ऀࡊ े ݵ ࡹؾٵ ґ ޅ ѽфս ה йࡊ ٵ ѹ 719 2 Step 3 Install the drain assembly Cut off the end of drain assembly for an appropriate length according to the depth of the drain assembly hole Put the sealing ring into the drain assembly...

Page 9: ...ps the cabinet Handle it gently to prevent damage Cabinet ѽ Step 5 Install the top cover Lift the top cover above the lavatory and lower it Visually check whether or not the position is proper If not it needs to remove the top cover and cabinet and adjust their positions before re installation Lift the top cover and lower it into the lavatory They must fit properly If not remove the cabinet and ad...

Page 10: ...water inlet of the thermostatic valve Connect another end with the cold water angle valve on the right Tighten them with a wrench 4 Connect one end of the other hose with the outlet of the thermostatic valve Connect the other end with the inlet of the solenoid valve assembly Tighten them with a wrench Note When there is a cold water valve only just connect one end of the hose with the cold water v...

Page 11: ...ment Knob ऄ ஂલਭ ޔ Pressure Regulator Adjustment Knob ६Թஂલਭ ޔ Step 8 Install the soap bottle 1 Prepare soap soap viscous water 1 8 or dedicated foaming soap The user can adjust the ratio according to the actual soap condition 2 Install soap taking pipe and screw the cover 3 Connect the wiring harness Pay attention to the direction of the connection Soap Taking Pipe 䤞 Harness Connector ߘি ףݎث Soap B...

Page 12: ...rogram A and B high and low speed of the fan heating on and off 3 Display board communication failure prompt If the communication fails between the main control panel and the display board the low wind speed indicator will blink to prompt a communication failure 4 Lavatory block up prompt If the lavatory block up causes the action of overflow switch the heat ON indicator on the keypad will blink to...

Page 13: ...he power button to OFF before switching other function buttons Select functions and switch the power button to ON If a power failure occurs after powering on again all functions default to those in the last operation Wind heat ON AUTO and OFF Lights on the right indicate the current mode default mode after power on is ON Wind speed HIGH and LOW Lights on the right indicate the current mode default...

Page 14: ...to blink After 1 second the outlets on both sides stop simultaneously 2 seconds after the white indicator turns off the fan starts and the red indicator turns on If the heater is on or in automatic mode while the ambient temperature is below 25 the heating function is activated After heating for 23 seconds the heater stops 2 seconds later the fan stops working and the red indicator turns off The p...

Page 15: ...pts that soap is coming out The red indicator prompts that dry hands with air White Indicator ग ࢰ Blue Indicator ࢰ Red Indicator ࢰ SIMPLE TROUBLESHOOTING Problem 问题 Analysis 判断分析 Solution 解决方法 Lavatory does not work 洗手盆不工作 A A power failure occurred A 停电 A Wait until the power is restored A 等到电力恢复 B Not plugged into the power outlet B 未接上电源 B Connect the power cord B 插上电源线 C The drain assembly is ...

Page 16: ...A 添加皂液 B Soap pump connection cable is not connected properly B 皂泵连接线未接好 B Connect soap pump wires B 对接好皂泵线路 C Soap dispenser pump is broken C 给皂泵损坏 C Replace soap dispenser pump C 更换给皂泵 Low wind speed 风速偏小 A Low speed wind mode A 低速风模式 A Adjust within the high speed and low speed mode A 调节高速和低速模式 B The HEPA filter is blocked because it has not been replaced for a long time B 过滤 HEPA 长时间未更换堵塞 B Rep...

Page 17: ...or a long time or you do not need this function please make water go through the soap taking pipe and repeatedly start the function until the water inside the pipe becomes clean Then remove the soap taking pipe and again repeatedly start this function to drain water from the soap pipe Then remove the connecting wires of the soap pump to stop starting the soap pump When you want to use the soap dis...

Page 18: ...d be well familiar with installation instruction 8 The hose must use the attached hose Do not use the old hose 9 If the water pressure is too high increase the relief valve 10 The ambient temperature of the product shall be higher than freezing temperature 11 The inlet water quality shall be municipal tap water which complies with GB5749 12 Do not pour water into the air outlet 13 The blockage sha...

Reviews: