4 — PROGRAM MENU PARAMETERS
Curtis Model 3150R – Oct. 2022
pg. 20
The programmable parameters allow you to configure the gauge so that it meets your application’s
requirements.
provide a user-friendly way to read and write to the
parameters.
Restart the device after you change a parameter marked as [PCF]. If the device is not restarted, a
Parameter Change fault will occur.
The parameters are grouped into menus. This chapter describes the main menu and the menus
contained by the Program menu. The gauge also provides read-only parameters on the
and
The following columns in the parameter description tables contain multiple types of information:
• Parameter and CAN Index: The parameter name, followed by the CAN index and sub-index.
This column also identifies parameters marked as [PCF].
Note: CAN indexes and sub-indexes are delimited by colons. For example, a parameter with an
index of
0x640F
and a sub-index of
0x00
would be represented as
0x640F:00
.
• Values and Raw Values: The allowed values as displayed in Curtis programming devices,
followed by allowed values in raw units suitable for CAN messages.
• Access Level and Default Value. The parameter’s access level for Curtis programming devices,
followed by the default value.
Note: Writes to parameters are automatically saved to the 3150R’s EEPROM. A “save” command
using the CANopen Store Parameters object (
0x1010:01
) is not required.