- 12 -
Setup Guidelines
Note 3: Switch on delay operation
Switch on delay specifies the delay time until a switch
turns ON.
Switch on delay is enabled when the
setting is set
to
, and the
setting is set to
.
Note 4: Cost rate
Cost rate is the rate specified in accordance with function
selection "
: display unit selection" setting.
Note 5:
Setting ranges
Setting ranges depend on the model number and display
unit. The table below shows the available ranges.
If a value that is greater than the maximum display value is set,
instantaneous flow rate output will be up to equivalent to the
maximum display value.
Do not set values that exceed the maximum display value for
instantaneous flow rate switch output 1 and instantaneous flow
rate switch output 2. The instantaneous flow rate may not reach
the set value during operation and may not work in the case.
selection value
Cost rate setting unit
00:
ℓ
/min,
ℓ
Per 1m
3
01: m
3
/h, m
3
02: m
3
/min, m
3
03: kg/h, kg
Per 1 kg
Setting value FAS-002 FAS-005 FAS-030 FAS-060 FAS-120
Remarks
00:
[ℓ
/min
]
0 to 800 0 to 2000 0 to 12000 0 to 24000 0 to 48000 Setting range
upper limit is
equivalent to a
400% FS flow
rate value.
01:
[
m
3
/h
]
0 to 48.0 0 to 120.0 0 to 720.0 0 to 1440.0 0 to 2880.0
02:
[
m
3
/min
]
0 to 0.800 0 to 2.000 0 to 12.000 0 to 24.000 0 to 48.000
03:
[
kg/h
]
0 to 62.1 0 to 155.2 0 to 931.0 0 to 1862.0 0 to 3724.0
● Instantaneous flow rate peak value display
①
While the instantaneous flow rate screen or integrated flow rate screen is
displayed, hold down the key for about two seconds.
This will change to the instantaneous flow rate peak value screen, which
alternate between
and the peak value.
②
To exit the peak value screen, press the
key. This will return to the
instantaneous flow rate screen or integrated flow rate screen.
・
To clear the current instantaneous flow rate peak value, display the peak
value and then hold down the key for about five seconds.
● Instantaneous flow rate lower value display
①
While the instantaneous flow rate screen or integrated flow rate screen is
displayed, hold down the key for about two seconds.
This will change to the instantaneous flow rate lower value screen, which
alternate between
and the lower value.
②
To exit the lower value screen, press the
key. This will return to the
instantaneous flow rate screen or integrated flow rate screen.
・
To clear the current instantaneous flow rate lower value, display the lower
value and then hold down the key for about five seconds.
● Information display
①
While the instantaneous flow rate screen or integrated flow rate screen is
displayed, hold down the
key for about two seconds.
This will change to the information screen, which alternate between the
display item and value.
②
To go to the next item, press the key. To go to the previous item,
press the key.
③
To exit the information screen, press the
key. This will go to the
instantaneous flow rate screen or integrated flow rate screen.
Display content list
Display item
Item content
Description
Model ID
ID that identifies the model.
FAS-002
→
0000
FAS-005
→
0001
FAS-030
→
0002
FAS-060
→
0003
FAS-120
→
0004
Range ID
ID that identifies the reference range
FAS-002
→
02000 (200. 0
ℓ
/min)
FAS-005
→
05000 (500. 0
ℓ
/min)
FAS-030
→
03000 (3000
ℓ
/min)
FAS-060
→
06000 (6000
ℓ
/min)
FAS-120
→
12000 (12000
ℓ
/min)
F/W version
Cost display (lowest digits)
Shows the cost.
Note 1
Cost display (highest digits)
Back flow rate integrated value (lowest digits)
Shows the back flow integrated
flow rate.
Note 2
Back flow rate integrated value (highest digits)
Cumulative integrated value (lowest digits)
Shows cumulative integrated value
since shipment.
This value is not returned to 0 by
integrated value reset.
Cumulative integrated value (highest digits)
Integrated value before integrated value reset
(lowest digits)
Shows the integrated value
immediately before an integrated
value reset was performed.
Integrated value before integrated value reset
(highest digits)
Note 1: The conversion rate can be changed by setting the cost
rate setting of parameter setting "
".
This item is not displayed when integrated countdown is
selected.
2: When the function selection "
" integration option is
set to
, the remaining back flow amount will be
displayed and decremented when there is normal flow.