background image

Low Temperature Torque Apparatus  

Operation and Instruction Manual 

 

K18854,55,64,65-Manual

    

 

-

10-

 

2  Safety Information and Warnings 

 

Safety 

Considerations. 

The 

use 

of 

this 

equipment  may  involve 

hazardous 

materials  and 

operations.  This  manual  does  not  purport  to 
address all of the safety problems associated with 
the use of this equipment. It is the responsibility of 
any  user  of  this  equipment  to  investigate, 
research,  and  establish  appropriate  safety  and 
health  practices and  determine  the applicability of 
regulatory limitations prior to use. 

 
Equipment  Modifications  and  Replacement 
Parts. 

Any  modification  or  alteration  of  this 

equipment from that of factory specifications is not 
recommended  voids  the  manufacturer  warranty, 
product safety, performance specifications, and/or 
certifications  whether  specified  or  implied,  and 
may result in personal injury and/or property loss. 
Replacement  parts  must  be  O.E.M.  exact 
replacement equipment. 
 

Unit  Design. 

This  equipment  is  specifically 

designed for use in accordance with the applicable 
standard  test  methods  listed  in  section  1.2  of  this 
manual. The use of this equipment in accordance 
with  any  other  test  procedures,  or  for  any  other 
purpose,  is  not  recommended  and  may  be 
extremely hazardous. 
 

Chemical Reagents Information. 

Chemicals and 

reagents  used  in  performing  the  test  may  exhibit 
potential  hazards.  Any  user  must  be  familiarized 
with  the  possible  dangers  before  use.  We  also 
recommend  consulting  the  Material  Data  and 
Safety  Sheet  (MSDS)  on  each  chemical  reagent 
for  additional  information.  MSDS  information  can 
be 

easily 

located 

on 

the 

internet 

at 

http://siri.uvm.edu 

or 

http://www.sigma-

aldrich.com. 

 

3  Getting Started 

 

The  instructions  for  preparing  the  equipment 

assume  that  the  user  is  aware  of  the  contents  of 
this  document, which lists the  warranty conditions 
and important precautions.

 

 

3.1  Packing List

 

 

 

Low Temperature Torque Apparatus

 with Test 

Rigs for ASTM D1478 (1) and ASTM D4693 (1) 
installed.  

 

K18860-0-43A

 Mounting Rod (1) 

 

K18860-0-43A

 Calibration Weights (4) 

 

K185-0-47B

 Bearing Packer (1) 

 

K185-0-51B

 Large Bearing Cup Remover (1) 

 

K185-0-51A 

Small Bearing Cup Remover (1) 

 

K185-0-50 

Bearing Installer (1) 

 

K185-0-56 

Bearing Cup Installer (1) 

 

K185-0-44 

Bearing Holder 

 

K18860-0-23 

Sleever Trust Indicator 

 

K18854-Manual

 

Low  Temperature  Torque 

Apparatus Operation and Instruction Manual 

 

Additional Accessories (purchased separately) 

 

 

K18871

 Data Acquisition Package 

 

289-001-006

 Test Bearing, 6204, for ASTM 

1478 

 

K18860-0-24

 Inboard Test Bearing, for ASTM 

D4693, LM-67010-LM-67048 tapered roller 
bearing 

 

K18860-0-16

 Outboard Test Bearing for ASTM 

D4693, LM-11910-LM-11949 tapered roller 
bearing 

 
Additional Required Materials  
 

 

1,1,1-Trichloroethane

 

WARNING:

 

 

– 

Harmful if Inhaled. High

 

concentrations may cause unconsiousness or 
death. Contact may cause skin irritation or 
dermatitis. Eye Irritant. May produce toxic 
vapors if burned.  

 

Stoddard Solvent 

WARNING:

 

– Combustable. Health 

Hazard. Keep away from heat, sparks, and open 
flames. Avoid build-up of vapors and eliminate 
all sources of ignition, especially non-explosion 
proof electrical apparatus and heaters. Avoid 
prolonged breathing of vapor or spray mist. 
Avoid contact with eyes and skin 

 

n-Heptane 

WARNING:

  

– Flammable. Health hazard. 

Keep away from heat, sparks, and open flames. 
Keep container closed. Use with adequate 
ventiliation. Avoid prolonged breathing of vapor or 
spray mist. Avoid prolonged or repeated skin 
contact.  

 

Laboratory Oven

  

Capable of maintaining 70 ± 3°C  

 

Ultrasonic Cleaner 

Bransonic 220 or Equivalent 

 

Nylon Spatula 

 

Run-in Stand for D4693 Test Bearing 

Summary of Contents for K18854

Page 1: ...mia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis Instrumen...

Page 2: ...Low Temperature Torque Apparatus Operation and Instruction Manual K18854 55 64 65 Manual 1...

Page 3: ...rque Apparatus was manufactured in conformance with the applicable standards set forth in this certification Specifications ASTM D1478 ASTM D4693 ASTM D4950 FTM 791 334 This unit is tested before it l...

Page 4: ...Low Temperature Torque Apparatus Operation and Instruction Manual K18854 55 64 65 Manual 3...

Page 5: ...Low Temperature Torque Apparatus Operation and Instruction Manual K18854 55 64 65 Manual 4...

Page 6: ...Low Temperature Torque Apparatus Operation and Instruction Manual K18854 55 64 65 Manual 5...

Page 7: ...information on subsequent processing or recycling prior to disposal of the equipment http www dpa system dk en WEEE Products Private or professional use Responsibility for Registration and Annual Repo...

Page 8: ...ely collected WEEE Mercury containing components such as switches or backlighting lamps compact fluorescent lamps CFL Batteries Printed circuit boards if the surface of the printed circuit board is gr...

Page 9: ...1 3 3 Setup 11 4 Descriptions 12 4 1 Instrument Controls 12 4 2 Temperature Controller Operation 12 5 Operation 14 5 1 Preparation for Operation 14 5 2 Operating Instructions 14 5 3 Calibration Proced...

Page 10: ...g needs Our products are backed by our staff of technically knowledgeable trained specialists who are experienced in both petroleum products testing and instrument service to better understand your re...

Page 11: ...instructions for preparing the equipment assume that the user is aware of the contents of this document which lists the warranty conditions and important precautions 3 1 Packing List Low Temperature T...

Page 12: ...medium otherwise damage may occur to the unit and the warranty will be void It is strongly suggested that a voltage stabilizer be used to prevent voltage variability The unstable voltage may cause dam...

Page 13: ...TM D4693 Test Rig Right side meter Over torque cut off feature The torque meter is equipped with an automatic cut off that interrupts power to the drive motor when measured torque exceeds a programmed...

Page 14: ...g device and the Process value displayed on the controller b Press the program key two times until PCt is displayed in the lower green LED display Press the DOWN key CAL will display on the lower gree...

Page 15: ...followed by the outer compression plate with the shoulder facing the hub Slip on the washer and thread on the nut but do not tighten 6 Carefully mount the test assembly in a vertical position in a vi...

Page 16: ...st Chamber After testing has been completed and the refrigeration system shuts down allow the test chamber to return to room temperature before wiping it dry with a clean cloth This will minimize fros...

Page 17: ...rod and slip on the weight marked 1 The strain gauge should display 11 lbs Each additional weight should register an additional 11 lbs Adjust the span screw to make any correction NOTE Handle weights...

Page 18: ...a suitable solvent and air dry Do not permit wet rigs to sit out as the components will corrode Wipe down the exterior of the cabinet using a soft cloth sprayed with household cleaner Over the course...

Page 19: ...Low Temperature Torque Apparatus Operation and Instruction Manual K18854 55 64 65 Manual 18 8 Wiring Diagrams 8 1 K18864 Unit Wiring 220 240V 60Hz...

Page 20: ...Low Temperature Torque Apparatus Operation and Instruction Manual K18854 55 64 65 Manual 19 8 2 K18865 Unit Wiring 220 240V 60Hz...

Page 21: ...turn of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the repair or...

Page 22: ...Low Temperature Torque Apparatus Operation and Instruction Manual K18854 55 64 65 Manual 21 Notes...

Reviews: