Chapter 4 Maintenance
MDC-2000BB Series
4-1
0093120012-01
Chapter 4
Maintenance
4.1 Maintenance
To operate the radar equipment in a good condition for a long period of time, perform the inspection and
cleaning periodically.
4.1.1 Monthly Inspection
(1) To protect the LCD and enhance the visibility, the acrylic filter is installed on the surface. If the
acrylic filter is dirty, an image cannot be clearly seen. If dirty, dip a soft cloth into a neutral
detergent, wring it lightly and wipe the filter surface lightly with the cloth. Do not use a dry cloth. If
done so, due to static electricity, the acrylic filter will attract dust.
(2) Check that the radiation surface of the antenna is not dirtied by soot. Dip a soft cloth into water or
soap water, wring lightly and wipe the antenna with the cloth. Check for damage and paint
sticking.
Note: Before performing the maintenance and inspection of the antenna, thread a string
through the hole of radome (upper) as illustrated below and hang it up.
Fixing screw
Hole
A : Top View
String
String
A
Radome (upper)
Radome (lower)
Caution:
Do not turn on the power of the radar during
inspection.
ensure
Caution
Never use a thinner solvent. The filter surface will be
chemically decomposed, resulting in the loss of the
transparency.
thinner
solvent
Summary of Contents for MDC-2000BB Series
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ... This page intentionally left blank ...
Page 25: ... This page intentionally left blank ...
Page 27: ...MDC 2000BB Series Chapter 1 Basic Operation 0093120012 01 1 2 ...
Page 96: ... This page intentionally left blank ...
Page 106: ... This page intentionally left blank ...
Page 111: ......
Page 112: ......