![Koden MDC-2000BB Series Operation Manual Download Page 45](http://html.mh-extra.com/html/koden/mdc-2000bb-series/mdc-2000bb-series_operation-manual_1984746045.webp)
MDC-2000BB Series
Chapter 2 How to use the menu
0093120012-01
2-8
2.12 Alarm
This mode is used when monitoring targets.
When targets enter in the set range or exit from
the set range, the buzzer notifies.
Two types [IN] and [OUT] are provided for the
alarm mode.
IN Mode
When a target enters within the specified range,
the alarm is issued.
This mode is used when watching targets which
are approaching to own ship.
OUT Mode
When a target exits from the specified range, the
alarm is issued.
Setting of Alarm Range
1
Press the [MENU] key.
2
Select [ALARM] → [ALARM MODE].
3
Change the setting of [ALARM MODE] with
the [ ] and [ ] keys.
ALARM MODE
IN
OUT
OFF
4
After selecting [IN] or [OUT], press the [ ]
key. Then, the alarm range can be set.
5
Move the cursor to the center of the alarm
range with the [ ], [ ], [ ] and [ ] keys.
6
Press the [ENT] key.
7
Change the distance direction with the [ ]
and [ ] keys and the bearing with the [ ]
and [ ] keys.
8
Press the [ENT] key. Then, the alarm range
is set.
9
Press the [MENU] key to close the menu.
The level of targets for alarm is set in [ALARM]
→ [DETECT LEVEL].
The alarm works when detecting the level higher
than the set level.
When [DETECT COUNT] is set, the alarm works
depending on the [ALARM MODE] setting.
[IN Mode]: The alarm works when targets enter
continuously into alarm area more than
[DETECT COUNT] value.
[OUT Mode]: The alarm works when targets
leave continuously from alarm area more than
[DETECT COUNT] value.
2.13 Sleep
The power OFF state and the transmitting state
are alternately repeated. This mode saves the
power consumption.
The sleep is used in combination with the
IN/OUT alarm.
For the setting of the alarm, refer to 2.17
Alarm.
Setup: OFF, 5MIN, 10MIN, 15MIN, (Initial value:
OFF)
1
Press the [MENU] key.
2
Select [ALARM] → [SLEEP].
3
Change the setting of [SLEEP] with the [ ]
and [ ] keys.
4
Press the [ENT] key to close the menu.
Operation during executing the sleep
During executing the sleep, the transmitting for
30 seconds is repeated at the interval of the set
time. If the IN/OUT of a target occurs during
transmitting, the buzzer beeps for alarm.
In case that the set time is set to 5 minutes, the
sleep works as follows.
Time
30 sec.
2 min.
30 sec.
2 min.
30 sec.
Hereafter
repeated
Antenna
Transmitting
Power OFF
Power On
(Countdown)
Transmitting
5 minutes
Summary of Contents for MDC-2000BB Series
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ... This page intentionally left blank ...
Page 25: ... This page intentionally left blank ...
Page 27: ...MDC 2000BB Series Chapter 1 Basic Operation 0093120012 01 1 2 ...
Page 96: ... This page intentionally left blank ...
Page 106: ... This page intentionally left blank ...
Page 111: ......
Page 112: ......