4-10
A-61676 June 2010
6. Reinstall
the separation roller cover and snap it into place.
7. Gently close the ADF door and turn on the scanner.
Replacing the front and
back sensor rollers
There are two sensor rollers, a front sensor roller (the longer roller) and
the back sensor roller (the shorter roller). Both rollers should be
replaced at the same time.
1. Turn the scanner off.
2. Push the ADF door release button to open the ADF door.
3.
Front sensor roller:
Remove the front sensor roller by grasping
both ends of the roller and lifting the roller out of the holder.
4. Take the new front sensor roller (the longer roller) and place it in the
right slot first, then the left slot. The white gear should be to the left.
Front sensor
roller