A-61500 January 2004
6-7
Operator Log Message
Description/Action
Lamps not ready for scanning
Scanning was attempted before the lamps were warmed up.
Wait until the lamps have completely warmed and try to scan
again.
Lamps ready for calibration
The lamps are warmed and the scanner is ready for calibration.
Lamps ready for scanning
The lamps are warmed and scanning can now be started.
Lamps timed out
The lamps were turned off due to inactivity.
Lower imaging guide dirty
The lower imaging guide is dirty. Follow the cleaning procedures
outlined in Chapter 5,
Maintenance
to clean the imaging guides.
Missing feed module or sensor error
• The feed module is not installed or not installed properly. See
Chapter 5,
Maintenance
for correct installation procedures.
• There is too much paper in the elevator tray and it is holding
the feed module up. Elevator tray capacity is 500 sheets.
Remove some documents from the elevator tray.
• Clean the sensors.
If the problem persists, call Service.
Multi-feed detected
A multi-feed has been detected due to an ultrasonic multi-feed
condition. Always check your host monitor to verify images as
overlapped documents may need to be rescanned. This
condition may be caused by poor document separation; replace
the separation roller tires and pre-separation pad. See Chapter
5,
Maintenance
for procedures.
Multi-feed detected
A multi-feed has been detected and the transport has stopped.
Clear the multi-feed and re-enable the scanner. Always check
your host monitor to verify images as overlapped documents
may need to be rescanned. This condition may be caused by
poor document separation; replace the separation roller tires
and pre-separation pad. See Chapter 5,
Maintenance
for
procedures.
Multi-feed detected, transport
stopped
A multi-feed has been detected and the transport has stopped.
Always check your host monitor to verify images as overlapped
documents may need to be rescanned. This condition may be
caused by poor document separation; replace the separation
roller tires and pre-separation pad. See Chapter 5,
Maintenance
for procedures.
Multi-feed length detected
A document was measured which exceeded the configured
maximum allowable length. This may be due to a document
overlap.
No paper in elevator tray
The scanner was started with an empty elevator tray. Place the
documents you want to scan into the elevator tray and try again.
Page on demand complete
Informational message. The scanner has completed scanning
the requested number of documents.
Pod door closed
The pod was closed.
Pod door opened
The pod is not closed completely.
Power on self-test successful
Informational message. The scanner powered on successfully.