MIM-
MIM 01/0419
page
57
ISDU
[hex]
Name
Description
Factory
default
value
Max
value
Min
value
Length
(Bytes)
Data
type
Access
(5)
–
gal
UK
(6)
‐
Barrel
0x035F
UserUnit
User
Unit
used
for
volume
1,0
9999,9
0,0
4
FloatT
R/W
0x0389
Value
Saved
volume
value
in
unit
according
to
setting
volume
unit
0,0
999999,0
‐
999999,0
4
FloatT
R
Temperature
0x03C2
Unit
Unit
used
for
temperature
1
(0)
‐
USER
(1)
‐
°C
(2)
‐
°F
1
UIntegerT
R/W
0x03C3
UserUnit
User
Unit
used
for
temperature
1,0
9999,9
0,0
4
FloatT
R/W
0x03DC
SimMode
Mode
of
the
Simulation:
Static,
Triangle
or
Monotonic
0
(0)
‐
Static
(1)
‐
Triangle
(2)
‐
Monotonic
1
UIntegerT
R/W
0x03DD
SimStartValue
Value
to
start
with
the
simulation
0,0
9999,0
‐
9999,0
4
FloatT
R/W
0x03E1
SimIncrementValue
Incrementation
value
of
the
simulation
10,0
999,0
‐
999,0
4
FloatT
R/W
0x03E5
SimNumberIntervals
Number
of
intervals
to
simulation
20
65000
1
2
UIntegerT
R/W
0x03E7
SimTimingIntervals
Timinig
[ms]
between
intervals
50
50000
50
2
UIntegerT
R/W
0x03ED
Value
Saved
temperature
value
in
unit
according
to
setting
temperature
unit
0,0
999999,0
‐
999999,0
4
FloatT
R
Part
Volume
0x0421
CountingType
counting
type
for
volume
slot
‐
>
absolute
or
bidirectional
0
(0)
‐
absolute
(1)
‐
bidirectional
1
UIntegerT
R/W
0x0426
Unit
Unit
used
for
part
volume
1
(0)
‐
USER
(1)
‐
L
(2)
‐
mL
(3)
‐
m3
(4)
–
gal
US
(5)
–
gal
UK
(6)
‐
Barrel
1
UIntegerT
R/W
0x0427
UserUnit
User
Unit
used
for
part
volume
1,0
9999,9
0,0
4
FloatT
R/W
0x0440
SimMode
Mode
of
the
Simulation:
Static,
Triangle
or
Monotonic
0
(0)
‐
Static
(1)
‐
Triangle
(2)
‐
Monotonic
1
UIntegerT
R/W
0x0441
SimStartValue
Value
to
start
with
the
simulation
0,0
9999,0
‐
9999,0
4
FloatT
R/W
0x0445
SimIncrementValue
Incrementation
value
of
the
simulation
10,0
999,0
‐
999,0
4
FloatT
R/W
0x0449
SimNumberIntervals
Number
of
intervals
to
simulation
20
65000
1
2
UIntegerT
R/W
0x044B
SimTimingIntervals
Timinig
[ms]
between
intervals
50
50000
50
2
UIntegerT
R/W