MIM-
page 56
MIM 01/0419
ISDU
[hex]
Name
Description
Factory
default
value
Max
value
Min
value
Length
(Bytes)
Data
type
Access
0x01CD
ServiceUserMenu
Locked
Whether
main
menu
is
locked
or
not
0
(0)
‐
not
locked
(1)
‐
locked
1
UIntegerT
R/W
0x01CE
SimulationAutoStop
Auto
stop
for
Simulation
after
time
in
minute
10
31
1
1
UIntegerT
R/W
Misc
0x01D0
LanguageSelection
Language
selection
0
(0)
‐
English
(1)
‐
German
(2)
‐
French
(3)
‐
Spanish
1
UIntegerT
R/W
0x01D8
OperatingHoursCount
Operating
hours
counter
0
429496729
6
0
4
UIntegerT
R
Flow
0x02F6
CutOff
Cut
off
for
flow
value
0,0
MRE
0,0
4
FloatT
R/W
0x02FA
Unit
Unit
used
for
flow
1
(0)
‐
USER
(1)
‐
L/m
(2)
‐
mL/m
(3)
‐
L/h
(4)
‐
m3/h
(5)
‐
galUS/m
(6)
‐
galUS/h
(7)
‐
galUK/m
(8)
‐
galUK/h
1
UIntegerT
R/W
0x02FE
UserUnit
User
Unit
used
for
flow
1,0
9999,9
0,0
4
FloatT
R/W
0x0317
SimMode
Mode
of
the
Simulation:
Static,
Triangle
or
Monotonic
0
(0)
‐
Static
(1)
‐
Triangle
(2)
‐
Monotonic
1
UIntegerT
R/W
0x0318
SimStartValue
Value
to
start
with
the
simulation
0,0
9999,0
‐
9999,0
4
FloatT
R/W
0x031C
SimIncrementValue
Incrementation
value
of
the
simulation
10,0
999,0
‐
999,0
4
FloatT
R/W
0x0320
SimNumberIntervals
Number
of
intervals
to
simulation
20
65000
1
2
UIntegerT
R/W
0x0322
SimTimingIntervals
Timinig
in
ms
between
intervals
50
50000
50
2
UIntegerT
R/W
0x0328
Value
Saved
flow
value
in
unit
according
to
setting
flow
unit
0,0
999999,0
‐
999999,0
4
FloatT
R
Volume
0x0359
CountingType
counting
type
for
volume
slot
‐
>
absolute
or
bidirectional
0
(0)
‐
absolute
(1)
‐
bidirectional
1
UIntegerT
R/W
0x035E
Unit
Unit
used
for
volume
1
(0)
‐
USER
(1)
‐
L
(2)
‐
mL
(3)
‐
m3
(4)
–
gal
US
1
UIntegerT
R/W