Heinrichs Messtechnik GmbH
OPERATING MANUAL TMU-W / UMC4
Page 73 of 118
TEMPERATURE functional class
The TEMPERATURE functional class is comprised of the functions that affect the lower- and the upper-range
value and the processing of the measured temperature. The additional service functions shall not be described
in this manual. Modifications can only be made in Programming mode (see 7.1.2 Operating modes), which
means that a correct password (see 7.1.5.3, “Passwords” and 7.2.2, “PASSWORD functional class”) must be
entered.
TEMPERATURE
Temperature
lower range val.
Temperature
upper range val.
TEMPERATURE
functional class
Temperature
0% = - 010 °C
Temperature
100% = + 100 °C
Temperature limit
MIN
MIN. temperature
- 050 °C
Temperature limit
MAX
MAX. temperature
+250 °C
Max. measured
temperature
Temperature
unit
Temperature in
[°C]
_____________
°C
°F
K
permissible +250 °C
measured +197°C