![KNECHT W 200 II Operating Instructions Manual Download Page 34](http://html1.mh-extra.com/html/knecht/w-200-ii/w-200-ii_operating-instructions-manual_1979913034.webp)
35
8. Care and maintenance
8.1 Coolant additive
It is imperative to add a rust-suppressing coolant additive to the coolant (see Chapter 8.1.1).
ATTENTION
No other coolant additives may be used
without the approval of KNECHT Maschinen-
bau GmbH.
8.1.1 Cooling lubricant maintenance plan
• Check fill level daily.
• After topping up with water, always measure the concentration and if necessary top up with
cooling lubricant.
• Check cooling lubricant concentration weekly.
Cooling lubricant:
Colometa SBF-PN
Refractometer °Brix: 3 - 5
Date:
°BRIX
Conc %
Remarks
etc.
Signature
(The value read off in °Brix multiplied by 1.8 is the concentration in %).
The concentration must always be between 3 - 5 °Brix (corresponds to a concentration of 5 - 9%).
Check the odor and appearance of the cooling lubricant regularly. The cooling lubricant must
be replaced at least every three months (biological hazard due to germ formation in the cooling
lubricant).