CONDENSATE ESCAPING THROUGH THE MASONRY.
ELEMENTS TO CHECK
ORIGIN
Flue gas channel
Flue
Condensate tray
Use of inadequate material;
Absence or installation not performed state-of-the-
art of the relevant condensate collector with drain
and connected to the disposal system.
SELF-COMBUSTION INSIDE THE FLUE.
ELEMENTS TO CHECK
ORIGIN
Hood fitting/flue gas channel
Flue gas channel
Flue
Periodical cleaning not performed.
WATER INSIDE THE FIREPLACE HEATING SYSTEM.
ELEMENTS TO CHECK
ORIGIN
Flue
Chimney
In total or partial absence of the chimney, the flue
is not realised with start parallel to the appliance.
Inadequate chimney.
Pump thermostat
Pump start-up at temperatures that are too low
(condensate is created).
To prevent flue gas from escaping at the time of loading the wood,
close the primary air front slots completely and fully open the smoke
damper.