Ultrasonic Level Meter
Operation Manual
你
If the upper surface of object at the lower part of the container is a plane,
the inlet for various media must be covered with a deflector set at certain angle.
Flat-top bulge at the bottom of the container – deflector required
The devices in the container such as pipe and support will affect the
measurement. For the design of measuring points, it must be ensured that no
other devices are within the diffusion range of ultrasonic wave signal.
Barrier in the container - pipe
The sensor shall not be installed in or above the charging feedstock flow
and it shall be kept from the feed inlet for certain distance.