3-2-1(b) Outdoor Unit
•
place free from the risk of combustible gas leakage.
• place which can bear the weight of the unit.
•
place which can bear the fixing strength of the outdoor unit.
•
Avoid a place subject to oil(including machine oil).
•
Avoid a saline place
•
Avoid a place subject to sulfide gas(hot spring zone).
(When installing the unit at such special environmental condi-
tions, it may cause machine trouble. When it is unavoidable to
use such places. It re q u i res special maintenance.)
•
A place where the discharge air and noise of the outdoor unit
do not disturb the neighborh o o d .
( Take special care not to cause any inconvenience to your
neighbors when installing the unit on the borderline with your
n e i g h b o rh o o d . )
• A place where strong wind does not head against the air outlet
of the outdoor unit.
(If a strong wind heads directly against the air outlet at the
time of cool operation, a safety device can be operated.)
•
Do not install the outdoor unit at an unstable place such as
outer wall of an apartment or building.
The outdoor unit may fall down, causing severe personal or
p roperty damage or loss.
•
If there is any unavoidable reason to install the unit at such a
place, take the following measures against the wind;
1. When installing the unit at a roadside concentrated with
buildings, install it parallel with the ro a d .
2. Install the unit so that the air outlet faces toward the wall at
a place such as rooftop, which may be subjected to stro n g
w i n d .
* Be sure to install the outdoor unit with consideration of service space.
3-2-1(a) Indoor Unit
• Install the unit at a place close to the wall facing the outside as it is
necessary to perform piping connection with the outdoor unit.
- It is effective to install the unit at a window side to ensure uniform
distribution of indoor temperature .
•
Install the unit at a place where there is no obstacle against the wind
a round the air inlet and air outlet.
•
Install the unit horizontally at a stable, rigid place.
(When installing the unit at a place subjected to vibration, noise may
o c c u r. )
•
Avoid a place near the door which is frequented by people.
• Avoid a place subject to direct sunlight.
3-2-1 Selection of Installation Place
3-2 Installationn
Above 100cm
Above 50cm
•Good method for using
space more efficiency.
Top view
Side view
Wall
Strong wind
Roof top
Above 10cm
Above 10cm
Above 50cm
Above 10cm
Above 50cm
Above 30cm
The air inlet faces toward the wall.
The air outlet faces toward the wall.
Space for piping
and wiring
Space for pip-
ing and wiring
Summary of Contents for KFH28PV2
Page 4: ...2 2 2 2 Dimensions Indoor Unit Outdoor Unit unit mm 330...
Page 26: ...Disassembly and Reassembly 4 5 No Parts Procedur e Remark...
Page 35: ...6 1 6 Exploded Views and Parts List 6 1 Indoor Unit...
Page 37: ...6 3 6 1 1 ASS Y COVER FRONT Exploded Views and Parts List...
Page 39: ...6 5 6 1 2 ASS Y GRILLE INLET Exploded Views and Parts List...
Page 41: ...6 7 6 2 Outdoor unit 19 18 14 1 16 17 15 7 6 9 11 13 12 8 2 4 5 19 1 19 2 10 3...
Page 46: ...8 1 8 PCB Diagrams 8 1 Ass y Main PCB CODE NO DB93 10531B...
Page 48: ...8 3 8 2 Ass y Power PCB Code No DB93 10532B...
Page 51: ...9 1 9 Wiring Diagrams 9 1 Indoor Unit...
Page 52: ...9 2 9 2 Outdoor Unit...
Page 54: ...10 1 10 Schematic Diagrams 10 1 Indoor Unit...
Page 55: ...10 2 10 2 Remote Control...