Operating Instructions and Installation
3-9
3-2-2 Electrical Work
Indoor and Outdoor Connection Wiring
Electrical Wiring
The electrical work should be performed by a specialist qualified for the work.
• Use the single phase power supply, and be sure to install the sub power distributing board for
exclusive use with the unit(separately purchased by the user).
• Avoid octopus-type wiring as it can cause a drop in voltage, thus resulting in poor performance of
the automatic control circ u i t .
•
Be sure to install the earth leakage circuit breaker (separately purchased by the user).
• Be sure to connect the grounding wire .
•
When connecting the connecting wire between the indoor and outdoor unit, be sure to align the
terminal block number with the connecting wire number.
•
When the connecting wire is not properly connected, it may cause tro u b l e .
Be careful not to allow connecting wires and power lines to get in contact with service valve or the
pipe without an insulator.
1 . Connect it to the terminal board N and L for power supply to the outdoor unit.
In so doing, peel off the end of the power cord by about 5mm, and press the cord to the ring ter-
minal for hooking.
2 . Perform the power grounding using the screw for exclusive use with the outdoor unit.
Electric power spec
Connecting wire & PCB fuse spec
Power
Sub switch
Fuse
Electric wire Below 20m
Allowable voltage
SPEC
Single phase 220V-240V~, 50Hz
30 A
30 A
3.5 mm
2
198V ~ 264V
Power cable
Connecting wire
Sensor cable
PCB fuse
TYPE
H07RN-F
H07RN-F
H05RN-F
H05RN-F
50T
F2L
SPEC
3G 2.5mm
2
450-750V~
5G 1.0mm
2
450-750V~
2G 0.75mm
2
300-500V~
2G 0.75mm
2
300-500V~
250V~, 3.5A
250V~, 2A
1. Connect the connecting wire to the terminal block and
connect the earth wire to the bracket earth.
2. Close the cover control.
3. As following the figure, firmly fix connecting wire with the holder cable.
Color of connecting wire
Model name
KRH28PV2
BRN
1
2
3
4
5
SKY
Thin BRN
BLK
Thin SKY
No.
Electric
panel board
Earth
Cover control
Cable clamp
Cable cover
Holder cable
Terminal block
Base control
Outdoor side
Terminal plate
A
B
C
Wire of sensor
Earth
Power cable
Summary of Contents for KFH28PV2
Page 4: ...2 2 2 2 Dimensions Indoor Unit Outdoor Unit unit mm 330...
Page 26: ...Disassembly and Reassembly 4 5 No Parts Procedur e Remark...
Page 35: ...6 1 6 Exploded Views and Parts List 6 1 Indoor Unit...
Page 37: ...6 3 6 1 1 ASS Y COVER FRONT Exploded Views and Parts List...
Page 39: ...6 5 6 1 2 ASS Y GRILLE INLET Exploded Views and Parts List...
Page 41: ...6 7 6 2 Outdoor unit 19 18 14 1 16 17 15 7 6 9 11 13 12 8 2 4 5 19 1 19 2 10 3...
Page 46: ...8 1 8 PCB Diagrams 8 1 Ass y Main PCB CODE NO DB93 10531B...
Page 48: ...8 3 8 2 Ass y Power PCB Code No DB93 10532B...
Page 51: ...9 1 9 Wiring Diagrams 9 1 Indoor Unit...
Page 52: ...9 2 9 2 Outdoor Unit...
Page 54: ...10 1 10 Schematic Diagrams 10 1 Indoor Unit...
Page 55: ...10 2 10 2 Remote Control...